Touring production RFP
venue technical advance

Research date 22 November 2026
Venues 18
Countries Australia 5 · Canada 5 · US 8
Sources 128
This is a source-led advance, not a venue-approved production plan. Every organizer-supplied capacity remains a planning input unless separately identified as a published venue figure. UNVERIFIED means no authoritative public source located or no event-specific confirmation; it is not a negative confirmation.

Event plan and interpretation

Organizer inputs: 150 minutes, two acts; 34 travelling; one venue per night; same-day load-in and load-out; doors 17:30; curtain 22:00; touring audio, lighting and video, with a small ground-supported lighting package if house rigging cannot carry the load. If 150 minutes is the full curtain-to-finish duration, the nominal end is 00:30 the following day. The report uses that arithmetic for curfew checks; confirm whether the 150 minutes includes any interval and the date-specific approved schedule with each venue.

A venue’s published capacity, point/line rating, outlet rating, room dimension, equipment inventory or standard operating window is not treated as approval for this event. Where the venue did not publish a detail, the table marks it UNVERIFIED and names the venue role or department to request it. Historical packs are labelled as such in their source notes and should be reconfirmed before contracting.

Australia

Hordern Pavilion

Sydney, Australia

16 unverified

Capacity: 3,000 is the organizer-supplied planning input only; it is not independently verified for the proposed configuration. The operator’s 2026 hire pack publishes configuration-specific capacities (including 3,000–3,300 full-capacity seated and 2,500–3,000 intimate concert) as venue configuration figures, not confirmation of this event’s sellable/approved capacity. Confirm event configuration and capacity with venue hire/operations and the promoter/house advance.

RiggingThe operator pack states “30-tonne central rigging capacity,” multiple rigging points across the perimeter roof, and that a rigging plan requires approval. It does not publish rigging-system type, point count, or maximum load per individual point: UNVERIFIED. The pack gives floor-to-stage-rigging-points height as 8 m. Whether the house can carry the touring lighting and video package is UNVERIFIED: package load is not supplied, and the published central capacity alone does not establish a comparison or sign-off. Whether ground support is required is likewise UNVERIFIED. Request the venue rigger/technical director’s current rigging plot and written load sign-off against the touring plot and itemized loads. The City says the Pavilion is not heritage-listed but has historic, associative, aesthetic and social significance; State-listed Centennial Parklands is adjacent. No rigging weight restriction is specified in that assessment: UNVERIFIED; confirm any conservation/structural restrictions with the venue technical director/building operations and relevant consent authority.
PowerThe operator lists 4 × 400 A outlets at the stage north-west side, with PowerLock and 32 A/3-phase connectors, plus additional 32 A/3-phase connections “throughout venue.” These are published outlet ratings/connectors, not a stated total building service capacity. Total service amps, supply voltage, exact phase/voltage for the 400 A outlets, and specific additional tie-in locations/distribution details are UNVERIFIED. Generator requirement and supplier are UNVERIFIED; decide only after the touring power schedule is compared with venue-confirmed supply. Ask the venue head electrician/technical services for a current power plan, tie-in specifications and load approval; confirm generator responsibility with the promoter/house advance.
Load-inThe operator publishes loading-dock door dimensions of 3.3 m wide × 3.8 m high and “level loading dock access directly into the venue,” with vehicle access on site. Other doors are listed as 1.2 m × 2.3 m. The pack does not state the number of dock doors: UNVERIFIED. Truck route/maximum vehicle size, truck parking or holding arrangements, freight-lift dimensions/capacity, and any alternative internal route are UNVERIFIED. A City assessment documents shared vehicular access via Driver Avenue connecting to Errol Flynn Boulevard and identifies an existing service/loading area, but gives no truck clearance or parking dimensions. Restrictions and venue-approved load-in/load-out window are UNVERIFIED; the same-day load-in/load-out plan is organizer-supplied and needs venue confirmation. Ask building operations/venue production for truck access, route, dock count, lift/route plan, restrictions and access window; ask promoter/house advance to confirm same-day schedule and labor calls.
StageThe operator lists a modular, portable stage measuring 12 m × 18 m, adjustable from 0.9 m to 1.4 m high, rated 600 kg/m². The pack does not identify which dimension is width versus depth, so usable stage width/depth orientation is UNVERIFIED and must be confirmed for the proposed stage layout. Floor-to-stage-rigging-points height is stated as 8 m, not stage-clearance height. Proscenium/thrust arrangement, deck surface/finish, and whether additional risers are needed or available are UNVERIFIED. Ask venue production/technical services for the stage plan, deck specification, configuration and riser inventory; confirm the selected stage and load with the promoter/house advance.
Curfews and restrictionsFor the supplied 22:00 curtain and 150-minute show, the nominal end calculated from organizer inputs is 00:30. The City’s Hordern refurbishment assessment says the project made no change to operational management and that proposed hours/operational measures accord with overarching site Management Strategies; it does not state a Hordern indoor-concert hard end time or numeric sound limit in the reviewed assessment. It also records that noise review was subject to conditions protecting the premises’ existing acoustic integrity. A venue-specific hard event end/curfew, event sound limits and any permit conditions applicable to this date are UNVERIFIED; no documented exact hard end was established, so a curfew conflict with 00:30 cannot be determined. Jurisdiction for event labor and staffing/union rules are also UNVERIFIED in public venue materials. Ask venue building operations/production and promoter/house advance for applicable consent/permit conditions, sound limits, hard end and staffing/labor requirements; ask the relevant consent authority for confirmation of permit conditions.
House-provided equipmentThe 2026 operator pack lists a K2 PA system (JPJ Audio): 16 K2 enclosures, 16 SB28 subwoofers, 8 ARCS including front fills and LL-RR, 5 LA8 amplifier racks, and full drive and multicore system; its monitor-system list includes Clair wedges, R-4 Series III enclosures and ML18 sub-low enclosures with amplifier racks. It also lists an in-house integrated RGBW programmable house-light system with custom zones and DMX compatibility for externally hired lighting desks, and truss-mounted curtains on west, east and south sides. The pack does not specify whether PA/monitor systems or curtains are included in the event hire versus separately charged/rented, nor current event availability: UNVERIFIED. A touring lighting console, separate lighting fixtures, audio consoles and backline are not specified in the pack; their provision/availability is UNVERIFIED, not confirmed absent. Ask venue technical services for the current equipment inventory, inclusion/rental terms and availability, and the promoter/house advance to confirm supplemental rentals.
Production contactThe operator’s 2026 concert hire pack identifies Jason Oxenham under “Technical Services” and lists jason.oxenham@playbillvenues.com.au; the same pack lists 02 9921 5333 under bookings. The operator’s contact page independently publishes 02 9921 5333 as the venue phone and eventsinfo@playbillvenues.com.au as the general/media contact. The pack does not give a more specific job title or confirm that this is the assigned production manager for this event: assigned event production contact UNVERIFIED. Contact venue technical services/venue hire to confirm assignment and the correct event-day escalation number.

Sources consulted:

Australia

Palais Theatre

Melbourne, Australia (St Kilda, City of Port Phillip)

23 unverified

Capacity: Organizer-supplied planning capacity: 1,800; not independently verified. The separately displays 2,888 seats as a general venue capacity, not as confirmation of this event's configuration or the organizer's 1,800 planning figure.

RiggingGrid/rigging system type: UNVERIFIED; point count: UNVERIFIED; maximum load per point and allowable distributed loads: UNVERIFIED. Whether the house can carry the touring lighting-and-video package: UNVERIFIED. No comparison is possible because the touring package load is not supplied and publicly reviewed venue sources do not establish relevant rigging load limits; therefore ground-support requirement is also UNVERIFIED. Obtain the current certified rigging plot, structural allowable loads, and written plot/load sign-off from the venue rigger/technical director; provide package weights and point loads. The registers the theatre (VHR H0947; HO184) and identifies original/contributory interior fabric, including stage curtains and decorative lighting. This documents heritage significance, not a numerical weight limit or event-specific restriction; ask the venue rigger/technical director and building operations about attachment/protection restrictions and any required heritage clearance.
PowerService amperage: UNVERIFIED; phase: UNVERIFIED; voltage: UNVERIFIED; distro/tie-in location and connector details: UNVERIFIED. Generator need and generator supplier/responsibility: UNVERIFIED. Public provides no event electrical specifications. Request current electrical schedule, available capacity, tie-in locations, distro inventory, connection procedure, and generator policy from the venue head electrician/technical director; confirm any temporary-power approval with building operations/house advance.
Load-inDock-door count and clear dimensions: UNVERIFIED. Truck route, vehicle-height/weight limits, on-site truck standing/parking and overnight parking: UNVERIFIED. Freight-lift dimensions/capacity or the approved alternative route to stage: UNVERIFIED. Restrictions and load-in/load-out windows: UNVERIFIED. The organizer's plan is 34 travelling personnel, one venue/night, same-day load-in and load-out; these are planning inputs, not venue confirmation. Ask venue production/house advance and building operations for dock measurements, access drawings, vehicle rules, stage route, truck parking/loading permissions, crew access, and confirmed same-day schedule. The public gives no such measurements or access terms.
StageThe describes the original 1927 design as having a broad proscenium; this is historical description, not a current stage plan. Current usable width, depth and height: UNVERIFIED; current proscenium opening dimensions and any thrust configuration: UNVERIFIED; deck surface: UNVERIFIED; risers available/required: UNVERIFIED. Obtain the current stage plan, proscenium measurements, deck specification, and riser inventory/availability from the venue production manager/technical director or house advance.
Curfews and restrictionsFor an indoor entertainment venue, states there are no statutory operating-time restrictions, but music-noise limits become stricter in the night period. Its timing depends on day/public-holiday context: ordinarily the day/evening period ends 23:00 Monday–Friday, 22:00 Saturday or a day preceding a public holiday, and 22:00 Sunday/public holiday unless it precedes a public holiday, when the period ends at 23:00. The applicable limit is background-dependent and assessed under the Noise Protocol; the guidance does not establish a Palais-specific dB figure or permit condition. Organizer inputs are doors 17:30, curtain 22:00 and 150-minute show; nominal finish is 00:30 the following day. The show crosses into the relevant night-noise period; no published Palais hard end/curfew was located, so a hard-curfew conflict cannot be confirmed. Event-specific noise/permit conditions: UNVERIFIED. Labour/union jurisdiction and staffing rules: UNVERIFIED. Ask the venue manager/production manager or promoter/house advance for event licence/permit conditions, venue noise plan, any curfew/end-time requirement and house sound limits; ask City of Port Phillip and/or EPA Victoria about applicable permit conditions, and the venue production manager/house advance about staffing, labour and union rules. says the framework covers indoor entertainment venues and does not cover other potentially applicable laws, including local laws and planning requirements.
House-provided equipmentPublicly reviewed official venue sources do not publish a current included-house-equipment inventory. PA/system, consoles, lighting desk, fixtures, backline, drapes available for event use, and any included audio/lighting/video equipment: UNVERIFIED. Equipment explicitly not provided: UNVERIFIED. The heritage listing mentions historically significant original decorative lights and stage curtains, but does not establish their current operational condition, event availability, or inclusion in hire; do not treat them as touring inventory. Organizer's stated plan is full touring audio, lighting and video, with a small ground-supported lighting package if house rigging cannot carry the load; the package load and feasibility remain unverified. Request the current house inventory, included-vs-rental/chargeable status, operating condition, patch/technical data and exclusions from the venue production manager/technical director or house advance; obtain rigger sign-off for any flown package.
Production contactNamed public industry contact: Amanda Riddle, Venue Manager; email amanda@palaistheatre.com.au, identified for media and industry enquiries by the [9]. The venue's general phone is (03) 8537 7677 via the official [10]; a direct phone for the Venue Manager is UNVERIFIED. The public source does not identify a production manager/technical director by name. Ask the Venue Manager to route the RFP to the production manager/technical director, venue rigger and head electrician; venue bookings contact for hire availability is bookings@palaistheatre.com.au / 03 8632 2178.

Sources consulted:

Australia

The Tivoli

Brisbane, Australia

12 unverified

Capacity: Organizer-supplied planning capacity: 1,200; not independently verified. The venue publicly advertises ticketed-event standing capacity of 1,500 and seated-theatre capacity of 690, but those are venue-published generic configuration figures, not confirmation of the 1,200-person production configuration.

RiggingRigging-system type, point count, point loads and approved rigging plot: UNVERIFIED; no current Brisbane-specific technical specification establishing these was located. The City Council heritage citation describes the building as having a high gabled roof with exposed king-post trusses, but gives no rigging rating or permission. Whether the house can carry the touring lighting/video package: UNVERIFIED—no load limits or package load supplied, so comparison is impossible. Whether ground support is required: UNVERIFIED. Ask the Tivoli Production Manager/venue rigger or Technical Director for current rigging plot, certified point and structure limits, package load review, and written plot/load sign-off. The building is a Brisbane local heritage place; Council says a qualified-practitioner conservation study is necessary before action affecting heritage significance, but publishes no venue-specific rigging/weight restriction.
PowerService amps, phase/voltage, distro inventory, tie-in location/capacity, and generator need/supply responsibility: all UNVERIFIED; no Brisbane-specific public production specification was located. Ask the Production Manager/head electrician for current electrical schedule, tie-in and distro plan, confirmed touring demand compatibility, and whether a generator is needed and who supplies it (;).
Load-inDock/door count and dimensions, truck approach/height/turning limits, approved truck parking, freight lift dimensions/capacity, internal route/clearances, production load-in restrictions, and load-in window: all UNVERIFIED. The venue's public visitor FAQ says wheelchair access is at the front and guests may unload directly out front; that does not establish truck access or touring freight suitability. The venue hire page mentions an adjoining car park as an event space, not as confirmed truck parking. Same-day load-in/load-out is organizer-supplied; no public schedule or window confirms it. Ask the Production Manager/venue operations for dock/door dimensions, vehicle route and parking approval, freight route, restrictions, and available call window.
StageUsable stage width/depth/height, proscenium dimensions/configuration, thrust, deck surface/load rating, and riser availability/quantity: UNVERIFIED. Council's heritage citation describes a large internal space with a stage at the southern end, but provides no usable production dimensions or stage details. Venue marketing confirms two purpose-built performance stages but does not give dimensions or identify which stage applies to this RFP. Ask the Production Manager for current stage plan, dimensions/heights, deck specification, stage configuration, and riser inventory/availability.
Curfews and restrictionsBrisbane City Council says live-music venues in the Valley must hold an amplified-music-venue permit and Council may set permit conditions, including maximum noise levels. The local law's Schedule 1 contains time- and area-dependent noise criteria, not a published Tivoli hard end: Core Area A external LCeqT criteria are 90 dB during 10:00–midnight Sunday–Thursday and 10:00 Friday/Saturday to 01:00 the following day, and 80 dB at other times; Core Area B criteria are 88 dB during 10:00–23:30 Sunday–Thursday and 10:00–midnight Friday/Saturday, and 65 dB at other times. The law's measurement provisions distinguish the external point (1 m from premises) and nearby residential-room criteria; actual venue permit conditions set the internal limits. Tivoli's exact core-area classification and current permit conditions are UNVERIFIED. No official source reviewed publishes a Tivoli hard end/curfew or labor/union jurisdiction/staffing rule; each is UNVERIFIED. Organizer inputs imply a nominal show end of 00:30 (22:00 curtain + 150 minutes); because the event day, applicable area class and individual permit conditions are not established, whether the sound criteria change during the show is UNVERIFIED. The published noise criteria are not by themselves proof of a hard curfew or a conflict. Ask the promoter/house advance and Production Manager for current permit/noise-management conditions, applicable area, event date-specific sound limits and hard end; ask the Production Manager/venue operations for labor jurisdiction and mandatory staffing rules.
House-provided equipmentThe venue publicly describes two purpose-built performance stages and concert-grade sound and lighting; its 2026 event package says bookings include a purpose-built performance stage and integrated lighting and sound (;). These are general inclusion/marketing statements, not an itemized technical inventory. PA/system models, audio consoles, lighting desk and fixtures, video equipment, backline, drapes, and explicitly not-provided items: UNVERIFIED/not itemized publicly. Whether any equipment is included for this ticketed touring event versus rental/available by arrangement: UNVERIFIED. Ask the Production Manager/house advance for the current equipment list, event-specific inclusion and availability, rental options, and exclusions.
Production contactNamed production contact: Hugh Webb, Production Manager, The Tivoli ([14]). Direct email and phone: UNVERIFIED/not published on that page. Venue's published general contact is (07) 3852 1711 and hello@thetivoli.com.au ([13]); request Production Manager Hugh Webb. For ticketed gig/venue-hire routing, the contact page lists Kate Johnson, Venue Booker & Ticketing Manager, kate@thetivoligroup.com.au.

Sources consulted:

Australia

Governor Hindmarsh Hotel (The Gov)

Adelaide, South Australia, Australia (59 Port Road, Hindmarsh SA 5007)

28 unverified

Capacity: Organizer-supplied planning capacity: 600; not independently verified and not represented here as a venue-confirmed capacity. The City of Charles Sturt’s public profile gives a separate promotional ‘capacity of 1200’ without specifying room/layout basis, so it is not treated as an event-configuration confirmation.

RiggingGrid/system type: UNVERIFIED; point count: UNVERIFIED; maximum load per point: UNVERIFIED. Whether the house can carry the touring lighting and video package: UNVERIFIED—the package load is not supplied, and no relevant venue load limits were located. Whether ground support is required: UNVERIFIED; organizer notes a small ground-supported lighting package only if the house cannot carry its load, pending venue approval. The SA Heritage Register confirms this address is a State Heritage Place, but that listing states no rigging or weight limits; do not infer a structural restriction from heritage status alone. Obtain current rigging plot, structural/load documentation, heritage-related constraints and signed package-specific plot/load approval from the venue rigger/technical director.
PowerService amps: UNVERIFIED; phase: UNVERIFIED; voltage: UNVERIFIED; distro availability/specification and tie-in location: UNVERIFIED; generator requirement: UNVERIFIED; generator supplier/responsibility: UNVERIFIED. Ask the venue technical director/head electrician or production manager for the current electrical schedule and event-specific power plan.
Load-inDock/receiving-door count and clear dimensions: UNVERIFIED. Truck access, permitted vehicle size, parking/standing and unloading route: UNVERIFIED. Freight lift dimensions/capacity or approved equipment route: UNVERIFIED. Loading restrictions and confirmed same-day load-in/load-out window: UNVERIFIED. No venue logistics specification was located in the public venue pages. Ask the production manager/house advance for the dock and route plan, truck instructions, access restrictions and confirmed schedule; same-day operations are an organizer requirement, not a published venue commitment.
StageUsable stage width, depth and height: UNVERIFIED; proscenium/thrust configuration: UNVERIFIED; deck surface: UNVERIFIED; risers required/available: UNVERIFIED. Ask the venue production manager/technical director for a current stage plan, dimensions, deck specification and riser inventory. The venue’s public functions material describes other function rooms and does not establish the touring stage specification.
Curfews and restrictionsVenue-specific documented sound limit, applicable permit/licence conditions and hard performance end/curfew: UNVERIFIED; no exact hard end time was located, so no curfew conflict can be determined. For the organizer’s 22:00 curtain and 150-minute duration, nominal show end is 00:30 the next calendar day; this is a calculation from organizer inputs, not venue approval. South Australia EPA guidance recommends an indoor-venue design criterion of music L10,15 below background L90,15 + 8 dB in any octave band at the nearest existing noise-sensitive location, and describes a separate criterion for noise-sensitive development; the guidance says the design criterion is not intended as a development-approval condition, and it does not establish The Gov’s actual operating limit or hard finish. South Australia’s official information says complaints about noise/behaviour at licensed premises go to Consumer and Business Services (CBS); this is a complaint/jurisdiction route, not a stated venue curfew. Labour/union jurisdiction and event staffing rules: UNVERIFIED. Ask the venue/promoter house advance or production manager for written site-specific licence/planning conditions, sound criteria, hard end, staffing call and any applicable labour/union requirements; ask CBS or the relevant planning authority to confirm regulatory conditions if needed.
House-provided equipmentPA/system and coverage: UNVERIFIED; house audio console: UNVERIFIED; lighting desk and fixtures: UNVERIFIED; backline: UNVERIFIED; drapes: UNVERIFIED. Whether any equipment is included, rented, subject to availability, or explicitly not provided: UNVERIFIED. No public touring-house-equipment inventory was located on the official venue pages and. Request the current technical specification/house inventory with included-versus-rental status and availability for the show date from the venue production manager/technical director/house advance.
Production contactNamed production manager/technical director and direct production email/phone: UNVERIFIED; no public technical-production contact was identified. The venue’s official contact page publishes general enquiries info@thegov.com.au and (08) 8340 0744, plus Function Enquiries Nat Edwards, functions@thegov.com.au, (08) 8340 4697, and band-booking contact Melissa Tonkin, Melissa@thegov.com.au; these roles are not identified as technical production contacts. Ask the venue’s general contact to route the RFP to the production manager/technical director or house advance.

Sources consulted:

Australia

Astor Theatre

Perth, Australia (659 Beaufort Street, Mount Lawley, WA 6050; City of Stirling local government area per)

32 unverified

Capacity: Organizer-supplied planning capacity: 1,400. This is not independently verified; the public and provide layouts but do not confirm this planning figure.

RiggingRigging/grid system type: UNVERIFIED; point count: UNVERIFIED; maximum load per point: UNVERIFIED. Whether the house can carry the touring lighting and video package: UNVERIFIED—the package load was not supplied, and publicly located venue and sources publish no rigging/load data. Ground support requirement and permission: UNVERIFIED; obtain venue rigger/technical director plot and load sign-off against the actual package, and confirm any ground-supported alternative. The State heritage register confirms the building is on the Register of Heritage Places; the entry does not state rigging or weight limits, so any heritage/structural restrictions are UNVERIFIED. Ask the Venue Manager, venue rigger/technical director, and building operations/heritage contact.
PowerService amperage: UNVERIFIED; phase: UNVERIFIED; voltage: UNVERIFIED; distro/tie-in locations and connector details: UNVERIFIED; generator required: UNVERIFIED; generator supplier/responsibility: UNVERIFIED. No electrical specification is published in the official venue or pages. Request the current electrical schedule and tie-in plan from the venue technical director/head electrician and building operations; confirm generator need and supplier through the promoter/house advance.
Load-inDock/loading-door count and clear dimensions: UNVERIFIED; truck access route, standing/parking location and restrictions: UNVERIFIED; freight lift dimensions/capacity or approved freight route: UNVERIFIED; load-in/out restrictions: UNVERIFIED; permitted same-day load-in/load-out window: UNVERIFIED. The venue's discusses general patron access/parking, not truck or freight access; its note that no lift serves the balcony does not verify freight-lift availability. Ask the Venue Manager/building operations and promoter/house advance for a truck route, access diagram, lift/route details, restrictions, and confirmed call window.
StageUsable stage width, depth and height: UNVERIFIED; proscenium versus thrust configuration: UNVERIFIED; deck surface: UNVERIFIED; whether risers are needed or available: UNVERIFIED. The official labels the stage but gives no dimensions or deck/riser specifications. Ask the venue technical director/production manager for a dimensioned stage plan and riser inventory/availability.
Curfews and restrictionsJurisdiction: City of Stirling; the City directs noise matters to the WA Environmental Protection (Noise) Regulations 1997. The State regulations set receiver-based assigned noise levels by premises classification and time, not a universal Astor-stage dB cap; for example, the Table 1 levels for a noise-sensitive highly sensitive area change at 22:00 to LA10 35, LA1 45 and LAmax 55 dB plus the influencing factor. The applicable receiving-premises category/influencing factor and any Astor-specific venue approval or event permit conditions are UNVERIFIED. No Astor-specific sound limit or hard finish/curfew was located in the official venue or municipal sources reviewed; therefore a documented hard-curfew conflict cannot be determined. Organizer inputs of 22:00 curtain and 150 minutes give a nominal end of 00:30 the following day; this is not confirmation that a 00:30 finish is permitted. Labour/union jurisdiction, minimum house crew, staffing rules and mandatory house personnel: UNVERIFIED. Ask the Venue Manager/production manager and City of Stirling Environmental Health for current venue/event approvals, receiver limits, monitoring point, start/finish conditions and permit requirements; ask promoter/house advance about crew rules and labour arrangements.
House-provided equipmentHouse PA/system and coverage: UNVERIFIED; audio consoles: UNVERIFIED; lighting desk and fixtures: UNVERIFIED; backline: UNVERIFIED; drapes: UNVERIFIED; explicitly not-provided inventory: UNVERIFIED; included house equipment versus rentals/availability: UNVERIFIED. The official, and pages located do not publish an equipment inventory or rental terms. Organizer-supplied plan states touring audio, lighting and video, with a small ground-supported lighting package if house support is inadequate; it does not verify venue equipment or rig capacity. Request the current house inventory/technical pack and itemized included-versus-rental availability from the Venue Manager/technical director/production manager.
Production contactNamed individual: UNVERIFIED; role publicly identified for hire inquiries: Venue Manager; email: manager@astortheatreperth.com ([28]); venue general email: hello@astortheatreperth.com; phone: UNVERIFIED. Ask the Venue Manager to route the advance to the production manager/technical director, head electrician and building operations as needed.

Sources consulted:

Canada

Queen Elizabeth Theatre

Vancouver, Canada

13 unverified

Capacity: Organizer-supplied planning capacity: 3,000; this is not independently verified. The current QET technical specification states a seating capacity of 2,765. Treat that as the published house seating figure, not confirmation that the proposed event configuration or a 3,000-person capacity is available; confirm seat kills, pit configuration, and approved capacity with VCT booking/production advance.

RiggingSystem: 74 single-purchase line sets plus 2 double-purchase line sets for side-stage lighting ladders; C-channel-style grid. Listed pipe battens are 80 ft long, Schedule 80, nominal 1.5-in pipe; maximum flying height is 72 ft for non-electric pipes and electrics stripped of cable. The spec lists 1,408 lb pipe capacity, 1,600 lb total arbor capacity and 1,400 lb working capacity less pipe weight; these are not stated as per-point structural working loads. The sheet identifies five 1-ton FOH point locations and two permanently installed 2-ton motors for touring PA; total rigging-point count and maximum allowable structural load per point are UNVERIFIED. The house’s ability to carry this touring lighting/video package is UNVERIFIED because package weights and rigging plot are not supplied and published figures do not establish a load comparison. Ground support requirement is UNVERIFIED. The City’s February 2026 Heritage Register lists Queen Elizabeth Theatre & Playhouse at 688 Hamilton St without a protection notation in that row; the policy advises title search to verify legal protection, and no heritage-specific rigging/weight restriction was located in the public technical material. Ask the venue rigger/Technical Director for the full allowable-load schedule, rigging plot/load sign-off, ground-support decision, and any building/heritage weight restrictions for the proposed package.
PowerPublished temporary power is 60 Hz, primarily 3-phase 120/208 V, with single-phase 125/250 V outlets also listed. Specified area totals: Upstage Left 600 A; Stage Right 800 A; Upstage Center 100 A; loading dock 200 A. The sheet lists individual tie-ins/outlets at those locations, including 400 A/200 A CAM-Lok circuits at USL and Stage Right and circuits marked tie-in required at Upstage Center and the dock. The overall building/service amp rating is UNVERIFIED; these location totals/outlets do not establish usable concurrent capacity for this show. Audio has a separately identified isolated-ground 200 A, 3-phase 120/208 V CAM-Lok at downstage-left proscenium for touring sound. Distro/tie-in location and connector details must be advanced with the house electrician. Generator requirement and supplier are UNVERIFIED because the show’s load schedule is not supplied and no public specification assigns a generator. Ask the Head Electrician/Technical Director to confirm concurrent amp availability, tie-in and distro plan, and whether a generator is needed and who supplies it.
Load-inThe spec lists two roll-up loading doors, each 20 ft wide x 16 ft high; dock height is 3 ft 5 in. Direct stage access is through two 4 ft x 16 ft doors (8 ft total width). Freight elevator: 6,000 lb capacity, 6 ft 4 in wide x 8 ft 8 in deep x 6 ft 11 in high, stated as access to basement dressing rooms; it is not specified as the stage route. One main angled bay accommodates a 53-ft trailer; a perpendicular secondary bay accommodates a 40-ft trailer if dropped. A cabless 53-ft trailer may be possible with road closure. Truck parking on the pad is not guaranteed and must be arranged in advance with the Technical Director; trucks cannot remain in the loading bay once unloaded. The spec says VCT’s truck traffic plan may require flaggers and road closures. Street parking is City-controlled and requires advance approval where applicable. The specific same-day load-in/load-out window, vehicle allocation and approved truck route are UNVERIFIED; standard VCT daily rental hours are 08:00–midnight, subject to the booking agreement. Advance the 34-person touring party, truck/bus count, arrival timing, traffic plan and post-show load-out with the Technical Director/house advance; obtain City street permits if needed.
StagePublished performing-area floor is 70 ft wide x 40 ft deep, maple with dark-brown stain and flex subfloor. Fixed proscenium opening is 68 ft 3.5 in wide x 31 ft 8 in high; stage floor to grid is 80 ft. Spec also gives 64 ft from proscenium line to rear wall. The venue is a proscenium stage; a thrust configuration is UNVERIFIED. Apron/pit geometry is described, including 16 ft from proscenium line to front of apron with pit raised, but this is not stated as a touring thrust. Risers are listed in multiple sizes/quantities as supplementary equipment shared between theatres and subject to prior reservation; availability for the date is UNVERIFIED. Ask the Technical Director/Head Stage Carpenter to confirm usable deck/apron dimensions for the show, thrust options, riser hold and configuration.
Curfews and restrictionsThe organizer’s inputs are doors 17:30, curtain 22:00 and a 150-minute show; nominal performance end is 00:30. No QET-specific hard performance end/curfew was located in public materials. VCT’s 2026/27 guidelines state standard daily rental hours of 08:00–midnight; that is a standard rental window, not a published hard show curfew, but the 00:30 nominal end falls 30 minutes beyond it and requires written confirmation/extension for performance and load-out. Vancouver Noise Control By-law 6555 applies citywide and sets sound limits measured at a point of reception that vary by source/receiver zone and sound type; for example, continuous sound received in a quiet zone is limited to 55 dBA daytime/45 dBA nighttime when the source is in a quiet zone, while non-continuous sound in all zones is limited to 75 dBA daytime/70 dBA nighttime. The by-law also sets commercial-premises amplified-music bass limits of 70 dBC daytime/65 dBC nighttime at the point of reception. These are general by-law limits, not a QET-specific sound allowance; applicable zoning/classification and sound category for this booking are UNVERIFIED. The QET house PA itself is specified as not designed to operate above 103 dBA A-weighted at the mix position; that is a system specification, not a municipal limit. The City’s noise-exception process expressly covers construction and special-event setup outside normal hours; permit applicability/conditions for this show’s sound and same-day load-out are UNVERIFIED. VCT stage/backstage work is under IATSE Local 118; FOH/Audience Services, Building Services and Stage Door Security are CUPE 15. Rentals include a Head Carpenter and House Electrician for up to 8 straight-time hours; additional crew are supplied through IATSE Local 118, with staffing determined by VCT Technical Department in consultation with Licensee. Ask VCT Booking/Event Coordinator and Production Manager for written approval of 00:30 end/over-midnight load-out, crew calls/staffing, applicable sound limits and permits; ask the City noise-permit contact to confirm jurisdiction and permit conditions.
House-provided equipmentHouse audio inventory: Meyer Mica/M’elodie L-R-C line arrays, 8 HP700 subs, 4 UPA and 7 M1D front fills; spec says system can be controlled from touring mixer and is not designed above 103 dBA A-weighted at mix. FOH console is Avid Venue S6L 24D; monitor console is Avid Venue S6L 32D and is shared between venues, so availability must be confirmed. Lighting desk: ETC EOS Ti with backup/RPU and listed control gear; technical sheet inventories house fixtures, including ETC Source Four fixtures, LED Vari-Lite fixtures and followspots, and describes a standard house hang. The tech package says detailed lighting plot/paperwork is available on request. House lighting inventory is stated, but whether each component is included in the rental or held for this booking is UNVERIFIED. Drapes listed include a dark-blue velour main curtain, black legs/borders/backdrops, black sharkstooth scrim and white translucent cyclorama. Supplementary stage equipment, including risers, is subject to prior reservation. House video system includes cameras, control/signal distribution and listed projection/screen equipment; the spec says video use adds costs, projector availability must be confirmed and the venue only confirms Full HD. Backline listed: Steinway 9-ft Model D and Yamaha upright; tuning is payable by lessee and the venue’s piano may not be used as a prepared piano. CD player: explicitly none. Availability and rental inclusion/pricing for house equipment are not established by the inventory; specific backline beyond the listed pianos is UNVERIFIED. Ask Production Manager/Technical Director and the relevant Head of Department to confirm what is included, reserved, or requires rental for this date.
Production contactPublicly listed technical contacts in the October 2026 QET specification: Brendan Keith, Technical Director, 604-665-3043, brendan.keith@vancouver.ca; Paul McManus, Senior Manager, Production, 604-665-3024, paul.mcmanus@vancouver.ca; Scott Ellis, Head Stage Carpenter, 604-665-2110, scott.ellis@vancouver.ca. General booking enquiries: vctbooking@vancouver.ca. These roles/contact details are published by VCT; the assigned show advance/production contact is UNVERIFIED. For technical rigging, power and staffing questions, start with the Technical Director/Production Department; for date booking and event terms, contact VCT Booking/Event Coordinator.

Sources consulted:

Canada

Winspear Centre (Francis Winspear Centre for Music), Concert Hall

Edmonton, Alberta, Canada

19 unverified

Capacity: 1,800 is the organizer-supplied planning capacity and is not independently verified. The venue’s public Concert Hall page lists 1,884 seats including the choir loft and 1,668 without it; those are published hall capacities, not confirmation of the requested 1,800 configuration.

RiggingGrid/system type: UNVERIFIED. Rigging point count and maximum load per point: UNVERIFIED. The public venue rental page describes production facilities but publishes no rigging plot or load limits. Whether the house can carry the touring lighting and video package: UNVERIFIED; package weights/load data were not supplied, so no comparison or house-load sign-off is possible. Ground support required: UNVERIFIED, not presumed; obtain a plot/load sign-off from the venue rigger/technical director. Heritage designation and any heritage or structural weight restrictions: UNVERIFIED. The venue history says the Centre opened in 1997 but does not establish heritage status or rigging limits.
PowerService amperage, phase and voltage: UNVERIFIED. Distro inventory and tie-in location: UNVERIFIED. Generator needed, and who supplies it: UNVERIFIED. No electrical schedule or tie-in specification is published on the venue’s public rental pages. Ask the venue head electrician/building operations and promoter/house advance.
Load-inThe venue says backstage facilities have access to the stage from loading docks, but dock count and door dimensions are UNVERIFIED. Truck route, height/weight clearance, staging/parking, freight-lift dimensions/capacity or alternate route, restrictions, and same-day load-in/load-out window: UNVERIFIED. The venue’s directions page notes road and sidewalk construction around the downtown venue, without specifying production truck access. Ask venue production/building operations and house advance for the current truck route, access plan, and confirmed schedule.
StageUsable stage width, depth and height: UNVERIFIED. Proscenium versus thrust configuration: UNVERIFIED. Deck surface and riser availability/requirement: UNVERIFIED. The public Concert Hall page identifies the Concert Hall/Main Performance Chamber but provides no stage plan or dimensional schedule. Ask the venue technical director/production manager for the current stage plot and riser inventory.
Curfews and restrictionsJurisdiction: City of Edmonton; the City says Community Standards Bylaw 14600 regulates community noise. Its public noise guidance says most noise is permitted only from 07:00–22:00 and notes that concerts/festivals may require a noise exemption permit. City permit guidance says community-level concerts/festivals held in City parks or on City property must conclude by 22:00, with extensions not guaranteed; it does not establish that this indoor Winspear booking is within that category or publish a venue-specific permit condition. The organizer’s 22:00 curtain plus 150-minute show gives a nominal 00:30 end, which runs beyond the City’s stated general 22:00 noise window and therefore merits written venue/City confirmation; no exact Winspear hard end time or confirmed permit applicability/conditions was located, so a venue curfew conflict is UNVERIFIED. Venue sound limits at the property line and any event-specific sound/permit conditions: UNVERIFIED. Labour/union jurisdiction and staffing rules: UNVERIFIED; ask venue production manager/house advance, and City event/noise-permit staff about municipal permit applicability.
House-provided equipmentPA: the venue’s June 2024 post reports installation of an L-Acoustics L Series system beginning January 2024. It describes arrays of two L2 and one L2D elements each and says that, at publication, left/right were installed and the centre array was planned for July 2024; current installed configuration, event availability, and included/rental terms are UNVERIFIED. Acoustic curtains and baffles: the same venue post says these were replaced in 2022 and describes their typical use for amplified versus acoustic shows; event configuration/terms should be advanced. Lighting desk, fixtures, video/projection equipment, backline, and other drapes: inventory, whether included, rental availability, and any items explicitly not provided are UNVERIFIED; the public rental pages do not state these details.
Production contactPublic rental contact: Diana de Sousa, Client Services Manager, 780-401-2522, dsousa@winspearcentre.com. The venue’s system announcement identifies Jonas Duffy as Head Audio Technician, but publishes no direct email/phone for him. A production manager/technical director’s direct contact is UNVERIFIED; contact the Client Services Manager and request routing to venue production/technical direction, head electrician, and venue rigger for advance and sign-off.

Sources consulted:

Canada

Big Four Roadhouse

Calgary, Canada

19 unverified

Capacity: Organizer-provided planning capacity: 2,000; not independently verified. The official venue page describes 118,000 sq. ft. across two levels and 60,000 sq. ft. on the upper level, which are area figures, not an attendance-capacity confirmation.

RiggingSystem/grid type: UNVERIFIED; the official guide does not publish a Big Four rigging plot or system description. Point count and maximum load per point: UNVERIFIED. The Stampede lists Encore as the exclusive rigging/truss service provider. Whether the house can carry the touring lighting/video package: UNVERIFIED; package load and venue rigging limits are both unavailable, so no load comparison or sign-off is possible. Ground support required or not: UNVERIFIED. Heritage or other structural/weight restrictions: UNVERIFIED; the guide does publish a 100 lb/sq. ft. floor-load capacity for Big Four Halls A, B and C, but that is floor loading and does not establish overhead rigging capacity. Ask the venue rigger/technical director for current plot, point ratings, constraints and written rigging-load sign-off against a supplied touring plot/load schedule; specifically confirm ground-support requirements and any heritage/structural restrictions.
PowerService amps, phase and voltage: UNVERIFIED for Big Four. Distro inventory and tie-in location: UNVERIFIED. Whether a generator is needed and who supplies it: UNVERIFIED; touring power demand is not supplied. The official guide describes electrical arrangements for the BMO Centre, not venue-specific Big Four service figures, so those details are not transferable. Calgary Stampede identifies in-house electrical/mechanical support generally. Ask the Big Four technical director/head electrician for service capacity, phase/voltage, tie-in and distro locations, and generator responsibility after providing the touring power schedule.
Load-inOfficial 2026 guide lists North and South ramp approaches for Big Four Roadhouse; each has a 10% / 12% ramp grade respectively and an interior door listed as 10 ft high × 12 ft 10 in wide. These are ramp/door entries, not confirmed exterior dock-door counts or exterior clearances; exterior door dimensions, full truck route/turning envelope, truck parking/overnight parking and permitted vehicle sizes: UNVERIFIED. Freight elevator dimensions/capacity and the approved equipment route to the upper-level venue: UNVERIFIED; no Big Four freight-elevator row is published in the guide’s elevator table. Load-in window/access hours: UNVERIFIED; same-day load-in/load-out is an organizer requirement, not a published venue window. The guide says assigned access points/current venue access information should be obtained from the Event Manager. Ask the Event Manager/house advance to confirm exact truck route, outside-door clearance, ramp use, freight route/lift, parking and same-day move-in/strike schedule.
StageA built-in stage is confirmed by the official venue page and operator guide (;). Usable stage width/depth/height: UNVERIFIED. Proscenium, thrust or other configuration: UNVERIFIED. Stage deck surface: UNVERIFIED. Riser availability/need: UNVERIFIED. The guide publishes Hall A and B room envelopes of 190.0 × 185.5 × 22.5 ft and 149.1 × 132.1 × 22.6 ft, respectively, and Hall C (lower) 337.3 × 129.2 × 11.4 ft; these are room dimensions, not stage dimensions. Ask the production manager/technical director for a current stage section/plan and confirm dimensions, configuration, deck finish and riser provision.
Curfews and restrictionsOrganizer schedule: doors 17:30, curtain 22:00, 150-minute show; nominal show end is 00:30 (calculated from organizer-supplied inputs). Venue-specific indoor sound limits and exact hard end/curfew: UNVERIFIED; no exact Big Four end time is published. The City of Calgary says a noise-exemption permit may authorize noise during restricted hours and may specify exact stop time and decibel limits; ordinary restricted hours begin at 10 p.m.. The City's 2026 Stampede page describes a midnight end for concerts outside Stampede Park and separate outdoor-speaker conditions during the Stampede period; these provisions are not a published Big Four indoor curfew. Thus no documented venue curfew has been found to compare with the nominal 00:30 end, and no conflict can be confirmed or ruled out; event-date and permit conditions are not provided. Labour/union jurisdiction, minimum crew/call rules and staffing ratios: UNVERIFIED. Stampede lists Encore as exclusive rigging/truss provider, but that does not establish union jurisdiction or required crew staffing. Ask the promoter/house advance and Event Manager for applicable permit conditions, sound limits/hard stop, event-date applicability, union/staffing rules and crew calls; ask City Event Services/311 about any required City approval.
House-provided equipmentConfirmed only at category level: venue/operator pages state that Big Four has in-house sound and lighting systems (;). Included house PA/system make/model/configuration, consoles, microphones, monitors, lighting desk and fixture inventory, video/projection, backline and drapes: UNVERIFIED; public sources do not itemize these or establish which items/services are included versus separately rented. No item is explicitly identified in the reviewed Big Four sources as not provided. Encore is identified as Stampede's preferred AV provider and exclusive rigging/truss service provider; this identifies service routing, not included equipment or rental availability. Ask the production manager/Encore for a current itemized Big Four inventory and a written distinction between included house equipment, separately available rentals and items not supplied, covering PA, consoles, lighting, video, backline and drapes.
Production contactNamed Big Four production contact, role, direct email and phone: UNVERIFIED; no venue-specific individual contact is publicly listed on the official venue contact page, which provides an inquiry form. Correct route: Calgary Stampede Venues/Event Services through that form; request the assigned Event Manager/production manager and a technical advance with the technical director/head electrician/venue rigger. Encore is listed as exclusive rigging/truss provider and preferred AV provider, but no Big Four-specific contact person is named on the Stampede page.

Sources consulted:

Canada

Burton Cummings Theatre

Winnipeg, Canada

22 unverified

Capacity: Organizer-supplied planning capacity: 1,800; not independently verified. An older 2018 venue information package states 1,579 total capacity, but also warns that exact specifications and equipment inventories may vary; this is not current validation.

RiggingHistorical 2018 venue-pack figure: grid live-load rating 50,000 lb; described as a four-line hemp fly system with 40-ft pipes plus five 32-ft steel counterweight electric lines; maximum load per line stated as 150 lb. The pack does not establish a certified rigging-point count or point-by-point load limits; UNVERIFIED. It cannot establish that the house can carry this tour’s lighting/video package: package weights and distribution are not supplied, and no current load plot or point ratings are public. House carry capacity for this package: UNVERIFIED. Ground support required: UNVERIFIED. Obtain current rigging plot, allowable point/line loads, and written plot/load sign-off from the venue rigger/technical director; do not conclude either house carry or ground support without it. The theatre is a designated National Historic Site; Parks Canada identifies the stage proper, original stage surface, fly tower, and related historic features as character-defining elements, but publishes no venue-specific suspended-load restriction. Heritage/weight restrictions: UNVERIFIED; ask venue technical director/building operations whether the proposed rigging or temporary ground support has restrictions or approval requirements.
PowerThe historical 2018 pack lists DSR 400 A 3-phase, DSL 500 A 3-phase, E1016 Camlock, two 50 A stove plugs, a bus-bar tie-in, and stage pockets of seven 15 A 110 V plus two 20 A 110 V. These are historical published values, not current confirmation; voltage for the 400/500 A services, exact service/tie-in locations and current connector/configuration are UNVERIFIED. Distro provision/house distro inventory: UNVERIFIED. Generator required: UNVERIFIED; package power demand and available current service details have not been compared. Generator supplier/responsibility: UNVERIFIED. Ask house technical director/electrician for current service schedule, voltage/phase, tie-in locations, permissible loads, distro/feeder arrangements, and generator responsibility after reviewing the tour power plot.
Load-inHistorical pack: loading area is in the rear alley at stage/street level; one set of double doors is described, 6 ft wide x 10 ft 6 in high, leading to upstage left. Alley access is identified from Donald Street or Ellice Avenue. Confirm current measurements and vehicle approach with the house technical advance. Truck/bus parking is described as limited and available upon request; street-parking/loading permits may be required. Exact truck dimensions/turning clearance, permitted parking location, and permit conditions: UNVERIFIED. Freight elevator dimensions/capacity and full dock-to-stage route: UNVERIFIED. Any route, weight, or access restrictions beyond the described door/alley: UNVERIFIED. A load-in window, including confirmation of same-day load-in and load-out for this event: UNVERIFIED; the same-day schedule is organizer-supplied, not a published venue commitment. Ask production advance/house technician and building operations for vehicle plan, door/route survey, any lift/stair dimensions, parking/permit approvals, and confirmed access hours.
StageHistorical 2018 pack lists 80 ft wall-to-wall width; 35 ft proscenium opening; arch height 36 ft; 36 ft from proscenium arch to upstage; 2.6 ft from arch to downstage; and 68 ft from deck to fly grid. It also says house drape creates a 32 ft x 32 ft performance area and describes a 17-ft wing. Usable clear height below rigging and current/verified dimensions: UNVERIFIED; request current ground plan/section and confirm the desired configuration with the technical director. Deck: pack states masonite on a sprung floor. Proscenium theatre; no thrust configuration is documented. Risers: whether needed or available is UNVERIFIED; ask production advance for current riser inventory and sizes. All figures are historical pending confirmation.
Curfews and restrictionsOrganizer inputs are doors 17:30, curtain 22:00, and 150-minute show; nominal end is 00:30 (22:00 + 150 minutes). Winnipeg’s Neighbourhood Liveability By-law prohibits unreasonable/excessive noise and provides a case-specific assessment, but the public text reviewed does not set a general hard end time or concert sound-level limit for this indoor performance. Its 21:00 restrictions apply to specified outdoor tools, construction/heavy equipment and vehicle-related activities, not a general concert curfew. A permit may authorize otherwise prohibited activity and may impose conditions; the City noise-permit application says apply at least four weeks before an event. Applicability to this indoor theatre show and any event-specific permit conditions: UNVERIFIED. No published hard curfew found; therefore no documented curfew conflict with the 00:30 nominal end is established. Labour: the historical pack says stage labour is supplied by NASCO and lists a four-hour minimum call, show call 30 minutes before curtain, meal penalty after five hours, overtime after eight hours, and statutory-holiday overtime; it says arrangements are through the house technician and staffing information is subject to NASCO confirmation. Current labour/union jurisdiction, mandatory staffing/headcount, electrician rules, and applicability to this date/show: UNVERIFIED. Ask the current house production/technical advance and NASCO labour coordinator.
House-provided equipmentPA: the 2018 pack says the in-house PA is owned by Sound Art and rented directly from them, at a separate cost not included in venue rental; Sound Art may also provide consoles and a full stage package. PA make/model, current configuration, coverage, current rental/availability, and included event provision: UNVERIFIED. The current operator rental page says facility rental excludes other costs including PA rental, electricians, and stagehands. Lighting: the historical pack lists GrandMA onPC with Command Wing and Fader Wing; 24 dimming channels; 22 Par 64, four Strand 6x12, one Altman Zoom, and 24 Chauvet Rogue 1 LED moving heads; it says current patch/plot/show file are available on request. Current inventory, condition, inclusion versus rental, and availability: UNVERIFIED. Video: pack lists a 16 ft x 9 ft upstage video board, 16:9, 1280 x 720 input; pack says no rental fee but technician fees apply. Current board/specs and availability: UNVERIFIED. Drapes listed in the historical inventory: 40 ft x 30 ft black velour backdrop; three sets of 10 ft x 30 ft black velour legs; four 50 ft x 10 ft black velour borders; guillotine show curtain. Current inventory and whether included or separately provided: UNVERIFIED. Backline: no public inventory or inclusion terms found; UNVERIFIED, not evidence of non-provision. The old pack cautions that inventory/specifications may vary. Ask house production advance for current inventory, included-vs-rental status, and what the event must bring; ask Sound Art specifically about PA and audio consoles.
Production contactA current public operator contact for general venue rentals is bctheatre@tnse.com, 204-987-7825. The operator page identifies this as rental information, not a named technical advance contact. [60] A 2018 venue pack names Ken Jackson, House Technician / Production Advance, 204-956-4912, kjackson@tnse.com; current identity/contact status is UNVERIFIED because the document is historical and warns specifications vary. Correct department to request: current venue production/technical advance or technical director, via the operator’s general rental contact. Do not treat the historical named contact as confirmed current.

Sources consulted:

Canada

Coca-Cola Coliseum

Toronto, Canada

13 unverified

Capacity: 6,000 — organizer-supplied planning capacity only; not independently verified. The venue history page gives historic/original capacity of 6,200 seats, not current event capacity:. Obtain the approved event configuration/capacity from the venue event coordinator.

RiggingThe current venue technical guide says beams run Stage Right to Stage Left and lists 49 ft floor-to-low-steel with rigging available; high steel is up to 73.5 ft with no rigging from high steel. End-stage rigging capacity is 50,000 lb total, on 14 ft × 9 ft 9 in centers, maximum 5,000 lb dead-hang per point; centre-stage capacity is 31,000 lb total, on 11 ft 3 in × 9 ft 9 in centers, maximum 5,000 lb dead-hang per point:. Grid/rigging-system type beyond the described beam arrangement and total point count: UNVERIFIED; ask the venue rigger/technical director for the rigging plot and available points. Whether the house can carry this touring lighting/video package: UNVERIFIED. Package load/point loads were not supplied, so published limits cannot establish capacity for this package; obtain venue rigger/technical director plot and load sign-off. Ground support required: UNVERIFIED; ask venue rigger/technical director after plot/load review. Heritage or special building-weight restrictions: UNVERIFIED; the guide does not state such restrictions or establish heritage-based limits; ask building operations/technical director for written confirmation and any structural restrictions.
PowerVenue guide lists one 400 A, 600 V, 3-phase disconnect at the north end of the bowl, upstage centre, with step-down transformers available per power requirement; it also lists one 200 A, 120/208 V disconnect in the loading area. Venue says it will drop what the event requires:. Other service amps/phase/voltage, distro inventory, exact tie-in/outlet locations, capacity allocation/availability, and whether a generator is needed or who supplies it: UNVERIFIED. Ask the venue event coordinator/house electrician or head electrician for a power plot and advance sign-off against the touring input list.
Load-inThe venue guide identifies a North Access Door measuring 12 ft 2 in high × 12 ft 1 in wide and three floor access ramps: northwest and north centre each maximum 10% grade; northeast maximum 8% grade. It states two outdoor event-truck parking spots at the loading area, with limited additional on-site bus/truck parking arranged through the event coordinator:. Dock-door count, truck approach/turning/height restrictions and parking allocation for this event: UNVERIFIED. Freight lift dimensions/capacity and approved freight route: UNVERIFIED. Load-in window and same-day move-in/move-out schedule: UNVERIFIED. Ask event coordinator/house advance and building operations for dock plan, vehicle routing, freight route, parking assignment and confirmed load-in/load-out calls. Guide confirms two 6,000 lb forklifts are available, but availability for this event must be advanced with the coordinator:.
StageThe venue's listed House Package includes a 40 ft × 60 ft stage:. The guide also gives arena flat-floor dimensions of 248 ft × 114 ft and concert floor of 200 ft × 85 ft subject to seating configuration; these are floor areas, not stage dimensions:. Usable stage width/depth for this event beyond listed package dimensions, stage height, proscenium/thrust configuration, and deck surface: UNVERIFIED; request current event-specific stage plan from event coordinator/technical director. Separate risers: availability/need UNVERIFIED; ask production/house advance. The venue lists a 40 × 60 ft stage in the House Package, but does not specify risers.
Curfews and restrictionsVenue-specific hard end/curfew: UNVERIFIED; the venue technical guide publishes no exact curfew. Given the organizer's 22:00 curtain and 150-minute show, nominal end is 00:30 (organizer inputs). Toronto Municipal Code Chapter 591 sets amplified/instrument sound limits at an outdoor point of reception in a living area: 55 dB(A)/70 dB(C) Leq over 10 minutes from 07:00–23:00 and 50 dB(A)/65 dB(C) from 23:00–07:00; indoor limits apply if an officer determines outdoor measurement is not reasonable. These are City noise standards, not a Coliseum show-end time:. The City states an approved exemption permit may allow amplified sound up to 85 dB(A)/105 dB(C) Leq over 10 minutes at the event property's lot line, subject to permit conditions: and. The 00:30 nominal end extends 90 minutes into the 23:00–07:00 period; this means the applicable City nighttime sound standard is relevant, but no venue-specific curfew or actual sound-limit conflict can be determined from public information. Ask promoter/house advance and venue event coordinator whether an exemption/permit applies and confirm the required event end with the City NoiseTO team. Venue guide states Exhibition Place union jurisdictions apply: IATSE Local 58 for stage and film/TV production workers, IBEW Local 353 for electrical, Carpenters Local 27, and LIUNA Local 506 for labourers/housekeeping; stagehands and riggers are IATSE crew with call based on production requirements. Confirm crew/staffing rules and calls with event coordinator/house advance:.
House-provided equipmentThe venue guide's House Package explicitly includes a 40 × 60 ft stage, up to 1,750 padded chairs, two forklifts, four followspot fixtures (operators additional), and in-house pipe and drape:. It also lists in-house bowl/arena lighting, four Lycian 3000 W xenon moveable spotlights, a centre-hung HD video display (four-sided main display, upper halo and four-sided lower scoring display), 16 ft × 9 ft projection screen/15,000-lumen projection, an HD control room, and three wireless microphones:. The guide does not identify a PA/system, audio or lighting consoles, fixture inventory beyond the listed spots/house lights, or backline as included in the House Package; their provision/availability is UNVERIFIED, not confirmed absent. Video-board and in-arena broadcast-system operation and event sound/lights are listed as additional house expenses/charges, not included equipment:. Ask event coordinator/house advance for current equipment inventory, inclusions versus rentals, availability, operators, patching and backline confirmation.
Production contactNo named production manager, technical director, or production email/phone is publicly disclosed in the sources reviewed: UNVERIFIED. Correct route is Coliseum Event Services / assigned Event Operation Coordinator (the technical guide says an Event Operation Coordinator is assigned after license execution and serves as operational liaison). The official booking page directs promoters to Event Services at coliseumrentals@MLSE.com; the public venue contact page lists main phone (416) 815-5982: and. Ask Event Services to connect the production manager/technical director, house rigger and head electrician for advance.

Sources consulted:

United States

Wellmont Theater

Montclair, New Jersey, USA

12 unverified

Capacity: 3,000 — organizer-supplied planning capacity, not independently verified. The venue’s history page separately describes audience capacity as “nearly 2500” in its account of the 2008 reopening; this is dated venue marketing, not a current certified capacity or confirmation of a production configuration.

RiggingRigging system type, point count, and maximum load per point: UNVERIFIED; no public technical plot or load limits located. Whether house rigging can carry the touring lighting and video package: UNVERIFIED. The package load is not supplied and venue load limits are unpublished, so no house-load comparison or carry approval is possible; ask the venue rigger/technical director for a rigging plot and written load sign-off. Whether ground support is required: UNVERIFIED; the organizer’s ground-supported-lighting fallback is a planning option, not a venue-confirmed requirement. The venue describes the theater as historic and dates its opening to 1922, but no source located states rigging weight or heritage restrictions for this venue. Montclair’s HPC says certificates apply to certain modifications to locally designated landmarks/district properties, but Wellmont’s specific designation status and applicability to this production are UNVERIFIED; verify with venue building operations and, if any building alteration is proposed, the Township HPC/Planning Department.
PowerService amps, phase, voltage, distro, tie-in location, generator requirement, and generator supplier: all UNVERIFIED. The venue’s public venue/contact pages do not publish electrical specifications. Request the electrical one-line/service details and generator decision from the venue technical director/head electrician or production manager; ask the promoter/house advance who supplies any generator.
Load-inDock-door count and dimensions, truck access/parking and permitted vehicle size, freight-lift dimensions/capacity or alternate route, restrictions, and venue-approved load-in window: all UNVERIFIED. The official contact page gives audience directions and nearby paid parking, not commercial truck routing or production loading details. Organizer inputs are one venue/night and same-day load-in/load-out; neither the window nor accommodation is venue-confirmed. Ask the production manager/house advance and building operations for the dock/route plan, vehicle limits, freight details, restrictions, and approved call times.
StageUsable stage width, depth, and height; proscenium/thrust dimensions; deck surface; and riser inventory/availability: all UNVERIFIED. The venue history page describes the 2008 reopening as restoring flexible floor seating around the original single stage, but gives no stage measurements or deck specification; this is historical venue description, not a technical drawing. Ask the technical director/production manager for a current stage plan, measurements, deck details, and riser availability/requirements.
Curfews and restrictionsNo venue-specific hard end time or event sound limit was found in the public venue pages or the reviewed Montclair ordinance. Montclair Chapter 217 §217-1 broadly prohibits unnecessary/physically annoying noise; §217-2 addresses sound-producing devices but says it does not prohibit a band or orchestra playing in a hall/building/open air. Those provisions specify no concert dB ceiling or hard end time. NJDEP states that its noise regulations for stationary commercial/industrial sources set 65 dB daytime and 50 dB nighttime, with nighttime beginning at 10:00 p.m.; whether/how that standard applies to this show, its measurement location, and any event-specific permit or exception are UNVERIFIED and need confirmation with venue building operations/house advance and the Township noise authority. Organizer inputs: 22:00 curtain and 150-minute show imply a nominal 00:30 end; that arithmetic is based only on organizer inputs. No published hard curfew establishes a direct conflict, but the nominal end is within NJDEP’s stated nighttime period, so applicable sound limits/conditions require confirmation. Labor/union jurisdiction, required crew, staffing minimums, call lengths, and overtime rules: UNVERIFIED; ask the production manager/house advance. The Township’s official Fire Department page lists fire permit forms but does not specify a concert curfew or production staffing requirements.
House-provided equipmentThe venue’s history page uses general descriptions—“new stage lighting” and a “cutting-edge sound system” in the 2008 reopening account, and a “state of the art audio visual experience” in its 2013 improvements account. These are dated marketing descriptions, not a current inventory, model list, or confirmation of what is included for this RFP. The venue’s private-event page says it has professional sound and lighting technicians who can design sound/light, but does not identify touring equipment or inclusion/rental terms. PA/system and monitor inventory, consoles, fixtures, backline, drapes, and any equipment explicitly not provided: UNVERIFIED; no public inventory found. Included house equipment versus rentals/availability is also UNVERIFIED. Request the current house inventory and itemized included/optional/rental status from the production manager/house advance, including sound, lighting, video, backline, and soft goods.
Production contactNamed production contact, role, and production email: UNVERIFIED; no named production contact or technical email was publicly disclosed on the venue contact page. The official page lists the general theater number (973) 783-9500 and an online message form, not a production-specific contact. Ask to be routed to the production manager or technical director/house advance; involve the head electrician and building operations for electrical and structural approvals.

Sources consulted:

United States

Theater at Madison Square Garden, New York, New York, USA (the operator’s current rental page labels it ‘Infosys Theater at MSG’).

New York, New York, USA

28 unverified

Capacity: Organizer-supplied planning capacity: 5,500; not independently verified and not treated as a venue-confirmed sellable capacity. MSG’s official rental page separately advertises 5,570 people ‘prior to production kills’—a generic operator capacity figure, not confirmation of this show’s configuration or available tickets.

RiggingGrid/rigging-system type: UNVERIFIED; point count and maximum load per point: UNVERIFIED; ask the venue rigger/technical director for the current rigging plot and certified point/load limits. House ability to carry the touring lighting/video package: UNVERIFIED. The package load has not been supplied and public sources located do not state applicable house load limits, so a comparison cannot be made; obtain venue-rigger/technical-director plot and load sign-off. Whether ground support is required or permitted: UNVERIFIED; ask venue rigger/technical director. Heritage or other weight restrictions: UNVERIFIED; the city planning source discusses MSG/Penn Station structural and operational interfaces but does not publish Theater rigging allowances or heritage/weight restrictions; ask building operations and the technical director.
PowerService amperage: UNVERIFIED; phase: UNVERIFIED; voltage: UNVERIFIED; distro availability and tie-in location: UNVERIFIED; generator need: UNVERIFIED; generator supplier/responsibility: UNVERIFIED. Ask the venue technical director/house electrician and production manager for electrical service, tie-in and distribution details and confirm generator approval/supply. The public MSG technical information reviewed does not state these values.
Load-inA NYC DCP report describes a Theater-specific separate loading entrance at the southern end of the complex’s Eighth Avenue frontage, accessible from West 31st Street via the southwest-corner open area. It recounts the submitted loading plan as using 1–2 trucks at a time backing onto the Eighth Avenue/31st Street corner plaza; Theater loading is described as relying on public streets/pedestrian circulation, and arena forklifts cannot internally access the Theater without significant building renovations. This is documented planning material, not an advance confirmation for this date. Dock/door count and dimensions: UNVERIFIED. Truck height/length/access limits, parking or staging allocation for this event: UNVERIFIED. Freight-lift dimensions/capacity and the complete equipment route: UNVERIFIED. Current restrictions/required public-space or street permits: UNVERIFIED for this event; have house advance/building operations confirm the approved loading plan and permits. Same-day load-in/load-out is an organizer-supplied plan, not a publicly verified house window; confirmed load-in/load-out window: UNVERIFIED. Ask venue production manager/house advance and building operations.
StageOperator-published stage floor height: 4 ft 2 in; proscenium opening: 22 ft high × 64 ft 3 in wide; stage depth at the proscenium: 30 ft. These are published venue figures, not a complete usable-stage plot. Usable stage width beyond the proscenium opening, usable depth/wing dimensions, and stage height reference datum: UNVERIFIED. Proscenium configuration is documented; thrust configuration/availability: UNVERIFIED. Deck surface: UNVERIFIED. Whether risers are needed, available, or included: UNVERIFIED. Ask the technical director/production manager for a current stage ground plan, section, surface specification and riser inventory.
Curfews and restrictionsShow timing from organizer: 22:00 curtain + 150 minutes = nominal 00:30 end; doors 17:30. No venue-specific hard end time or curfew was found publicly, so whether 00:30 conflicts with a house limit is UNVERIFIED; do not infer a curfew. NYC DEP’s commercial-music guidance covers live or recorded music from commercial establishments and describes nighttime limits from 22:00 to 07:00 for covered music that is unreasonable/disturbing: no more than 42 dB inside nearby residences and 7 dB above ambient measured on a street/public right-of-way 15 feet or more from the source. This is an environmental noise standard, not an indoor show SPL allowance or a published event end-time; whether/how it applies to this venue/event and any site-specific permit conditions must be confirmed with house advance and, as needed, NYC DEP/NYPD. NYPD states that a sound permit is issued for events requiring amplified sound by a device, with applications handled through the local precinct; the source does not specify whether this indoor venue performance requires one. Labour: MSG’s rental page identifies ‘multiple labor unions’ but does not identify applicable jurisdiction, staffing minimums, work rules, or touring/house calls; all those details are UNVERIFIED. Ask the venue production manager/house advance and MSG labor relations.
House-provided equipmentMSG’s event-rental page lists built-in audio/video, an in-house venue lighting system, two 16 ft × 9 ft side LED video displays, and a ‘Clair Brothers designed JBL Vertec system (Stacks & Racks).’ The page presents the lighting system, side LED displays and PA as available; it does not establish that they are included in the rental or available/configured for this date. Specific PA inventory/coverage and control package: UNVERIFIED beyond the above description. Audio and lighting console makes/models, lighting fixture inventory/plot, patching and control: UNVERIFIED. Backline: UNVERIFIED. Drapes/soft goods: UNVERIFIED. Items explicitly not provided: none identified in the public source; exclusions and rental/inclusion terms are UNVERIFIED. Ask the production manager/house advance for the current inventory, included-vs-rental schedule, and event-specific availability.
Production contactNamed production manager/technical director and direct production email/phone: UNVERIFIED; no named production contact is publicly identified in the sources reviewed. MSG publishes Special Events inquiries at 1-212-465-6106 and specialevents@msg.com; this is the public event-rental inquiry route, not a confirmed production-advance contact. Ask Special Events to route the RFP to the Theater production manager/technical director or house advance.

Sources consulted:

United States

Aragon Ballroom

Chicago, Illinois, USA

18 unverified

Capacity: 4,500 is the organizer-supplied planning capacity and is not independently verified. Live Nation’s event one-sheet markets capacity up to 4,000 and lists Ballroom capacities of 3,100 reception / 1,400 banquet / 1,600 theater; its current special-events page separately says groups up to 4,873. These are generic, format-dependent marketing figures, not confirmation of a 4,500-person touring-show configuration (;).

RiggingCurrent grid/rigging system type and plot: UNVERIFIED. A 2020 production-system press account reports the room had “single point rigging” and that weight was a factor; this is historical third-party reporting, not a current venue rigging specification or approval. Point count and maximum allowable load per point: UNVERIFIED. Whether house rigging can carry the touring lighting-plus-video package: UNVERIFIED—the package load is not supplied and public sources provide no applicable load limits. Ground support requirement: UNVERIFIED; do not plan on house support absent written sign-off. Heritage: City of Chicago’s Uptown Square district report lists Aragon Ballroom at 1100–1110 W Lawrence as a contributing property; the City landmarks ordinance requires Commission written approval for specified permit-triggering alteration/reconstruction/addition work, but does not establish event-specific rigging or load restrictions. Obtain current rigging plot, point locations/count and allowable loads, package-weight review, and written plot/load sign-off from the venue rigger/technical director; ask whether ground support is required and whether any landmark/building restrictions apply.
PowerService amps, phase and voltage: UNVERIFIED. Distro availability and tie-in location/capacity: UNVERIFIED. Whether a generator is needed and, if so, who supplies it: UNVERIFIED. Request current electrical/production specs and a load review from the venue head electrician or technical director; confirm generator and distro responsibility with house advance/promoter.
Load-inDock-door count and clear dimensions: UNVERIFIED. Truck access, route/turning clearance, truck parking or staging: UNVERIFIED; the public visit page gives the street address and recommends guest parking, not truck directions or truck parking. Freight lift dimensions/capacity and suitable freight route: UNVERIFIED; no freight specifications are published. Load-in restrictions and available load-in window: UNVERIFIED. The organizer’s same-day load-in/load-out plan is not venue-confirmed. Ask house advance/building operations for dock/door measurements, truck route and parking, freight lift or alternate route details, restrictions, and confirmed load-in/load-out schedule.
StageUsable stage width/depth/height: UNVERIFIED. Proscenium or thrust configuration: UNVERIFIED. Deck surface: UNVERIFIED. Riser availability/requirement: UNVERIFIED. The public floor-plan PDF labels Main Floor, Ballroom and Balcony but supplies no readable technical stage dimensions or deck/riser specification. Request a scaled current stage plan, proscenium/thrust details, deck surface and riser inventory from the technical director/production manager.
Curfews and restrictionsChicago Municipal Code §8-32-080 states that establishments holding a liquor license or public place of amusement license may not electronically amplify sound above average conversational level at 100 feet or more from the property line; it states no numeric dB value and no hard end time. Section 8-32-070 separately addresses public-way and private-open-space sound, including 10:00 p.m.–8:00 a.m. conditions, and is not itself an indoor-show curfew. No venue-specific permit conditions or hard end/curfew were located publicly. City DCASE describes its special-event permit application as for outdoor festivals, street fairs and athletic events, not a general indoor concert permit. Using organizer inputs, a 22:00 curtain plus 150 minutes gives a nominal 00:30 end the next calendar day. No published hard end was found, so a documented curfew conflict cannot be concluded; compliance with applicable property-line sound rules remains to be advanced. Current labor/union jurisdiction and staffing rules: UNVERIFIED. A 2020 industry account identified Aragon’s Head of Audio as an IATSE Local #2 stagehand, but it does not establish current jurisdiction, contract terms or required staffing. Ask house advance/production management for current hard end, event-specific sound/permit conditions and monitoring expectations, and labor jurisdiction, classifications, minimum calls and staffing requirements.
House-provided equipmentLive Nation markets a ballroom sound-and-lighting system and full production team, but the page does not give a current rider, itemized inventory, or inclusion/rental terms. Audio: a July 2023 industry report says Live Nation requested installation of a d&b KSLi system by Eighth Day Sound/Clair Global Integration and gives the reported configuration as 16 KSLi8 + 4 KSLi12, 8 SL-GSUB, 6 Yi10P, 18 D80 amplifiers and one DS10; this is a dated trade report, not a current availability/inclusion confirmation. FOH/monitor consoles, lighting desk and fixtures, touring video equipment/infrastructure, backline, and drapes: UNVERIFIED as to inventory, availability, inclusion or rental; no source explicitly identifies these as included or not provided. Request a current house inventory and item-by-item included/rental/not-provided status from house advance/production management.
Production contactNamed production manager, technical director or head electrician and direct production email/phone: UNVERIFIED. Public Live Nation special-event materials list ARAGONEVENTS@LIVENATION.COM and 312-923-2044 for the venue, and the linked floor plan lists 773-250-3013; these are published event contacts, not identified as touring-production contacts ([80]; [86]). The official visitor page lists aragonhelp@livenation.com and 773-561-9500 for guest information/accommodations, not production. Ask Live Nation venue production/house advance for the assigned production manager/technical director and current technical contact details.

Sources consulted:

United States

Greek Theatre

Los Angeles, California, USA

23 unverified

Capacity: Organizer-supplied planning capacity: 6,000; not independently verified. The venue’s public page describes a 5,900-capacity outdoor venue, while the City’s 2023 user-agreement report lists venue capacity as 5,901. Treat those as differing published general figures, not confirmation of the organizer’s requested configuration; ask Greek Theatre booking/house advance to confirm the bookable capacity and configuration.

RiggingRigging system type: UNVERIFIED; point count: UNVERIFIED; maximum load per point: UNVERIFIED. The City agreement says a comprehensive Greek Theatre technical package is available through the venue, but no current rigging plot or load schedule was exposed in the official public material reviewed. Whether the house can carry the touring lighting and video package: UNVERIFIED; ground support required: UNVERIFIED. The package load is not supplied, so no house-capacity comparison is possible; obtain a current plot/load sign-off from the venue rigger and technical director. The City calls the theatre historic and City Planning’s report identifies the Greek Theatre as a 1930 contributing feature of Griffith Park; no venue-specific weight or rigging restriction was found in the public sources reviewed. Ask building operations/structural engineer and venue rigger for any heritage-related approval or load restrictions.
PowerService amps: UNVERIFIED; phase and voltage: UNVERIFIED; distro/tie-in locations and connection type: UNVERIFIED; generator required: UNVERIFIED; who supplies a generator: UNVERIFIED. No venue electrical schedule was available in the public technical material reviewed. Ask the head electrician/venue technical director or production manager for current service, tie-in and generator requirements.
Load-inDock/door count and dimensions: UNVERIFIED. Truck approach, turning/access restrictions and production-truck parking: UNVERIFIED. Freight lift dimensions/capacity and the complete equipment route: UNVERIFIED. The venue’s private-events stage sheet lists “Street Level Load in Elevator,” but gives no lift dimensions/capacity or confirmation that this describes the touring freight route. The City agreement states that performance load-in may not begin before 7:00 a.m.; booking access time is set for the event, and load-out starts immediately after the event and must be complete by 2:00 a.m. the following day. Exact same-day load-in/out window and restrictions for this booking: UNVERIFIED; confirm with venue production manager/house advance and building operations.
StageUsable stage width, depth and height: UNVERIFIED; proscenium versus thrust configuration: UNVERIFIED; deck surface: UNVERIFIED; whether risers are needed or available: UNVERIFIED. The public stage/private-events sheet describes event use and an elevator feature, not performance-stage technical dimensions. Request current stage plot, clearances, deck and riser inventory from the technical director/production manager.
Curfews and restrictionsThe City’s published Greek Theatre user agreement says performances must end by 10:30 p.m. unless SMG grants prior written permission; in no case may a performance continue past the hard 11:00 p.m. curfew. Organizer inputs of 10:00 p.m. curtain plus 150 minutes yield a nominal 12:30 a.m. end on the following day; this conflicts with both the stated performance end and the hard curfew. Written permission to run later than 10:30 p.m. would not override the stated 11:00 p.m. absolute end. The same agreement sets a 95 dBA threshold sustained over any three-minute interval, triggering a warning and subsequent penalties; it does not specify the measurement location/method in the cited clause. Los Angeles Municipal Code §115.02 has general sound-amplification restrictions, including a 200-foot audibility limit and time/zone provisions, and recognizes duly authorized permittees; applicability or modifications for this event’s permit are UNVERIFIED. The City agreement’s default door opening is 90 minutes before advertised show time; approval of the supplied 5:30 p.m. doors against the actual advertised start is UNVERIFIED. The public agreement directs stagehands and production personnel through existing contracts with IATSE Locals 33, 706, 768 and 47; the venue determines minimum staffing for several event functions, but specific stagehand calls/crew minimums are UNVERIFIED. Ask SMG/house advance for current labor rules, crew calls, and the event-specific permit conditions; ask the City Department of Recreation and Parks/permit administrator about applicable municipal permit conditions.
House-provided equipmentThe City user agreement says SMG provides house sound, video displays and basic lighting systems originating at the front-of-house mix position, and requires use of the house audience PA. It allows the user to provide alternative/additional stage monitors and consoles, video displays and lighting. No make/model, inventory, console, fixture, or PA-system specifications are stated in that clause. Backline, drapes, risers, and specific consoles/fixtures: UNVERIFIED as included or available. The agreement does not expressly identify requested equipment categories as not provided; it does provide for extra charges for special facilities/equipment/services outside the included terms. Obtain the current inventory and availability from the production manager/house AV and lighting departments; do not assume unstated equipment is included.
Production contactProduction contact name, role, email and phone: UNVERIFIED. The official venue contact page does not publicly disclose a production/technical contact. The City agreement requires a detailed production advance to SMG at least ten days before the event but does not provide a technical contact in that clause. Request the Greek Theatre/ASM Global production manager or house advance contact; route rigging sign-off to the venue rigger/technical director and electrical questions to the head electrician.

Sources consulted:

United States

Cal Coast Credit Union Open Air Theatre

San Diego, California, USA

28 unverified

Capacity: Organizer-supplied planning capacity: 3,000 (input only; not independently verified and not represented as verified venue capacity).

RiggingGrid/rigging system type: UNVERIFIED; point count: UNVERIFIED; maximum load per point: UNVERIFIED. Whether the house can carry the planned touring lighting and video package: UNVERIFIED. Organizer reports a full touring audio, lighting and video package, with a small ground-supported lighting package if the house cannot carry the load; package weights/loads were not supplied, so no comparison or house-load conclusion is possible. Ask the venue rigger/technical director for current rigging plot, point ratings, and written plot/load sign-off. The venue’s official history says construction began in 1939 and the theatre opened in 1941; that history does not establish a heritage designation or any weight restriction, both UNVERIFIED. Ask the venue rigger/technical director and Facilities Operations Manager about structural/heritage restrictions.
PowerService amperage: UNVERIFIED; phase: UNVERIFIED; voltage: UNVERIFIED; distro and tie-in location(s): UNVERIFIED; whether a generator is required: UNVERIFIED; generator supplier/responsibility: UNVERIFIED. Ask the venue head electrician/technical director and production manager for service, tie-in, distro, and generator requirements. The identifies the production and facilities departments but publishes no power specification.
Load-inDock-door count and dimensions: UNVERIFIED. Tour-truck route, access/turning clearance, staging and truck parking: UNVERIFIED. Freight-lift dimensions/capacity and approved freight route: UNVERIFIED. Same-day load-in/load-out window and restrictions: UNVERIFIED; organizer’s same-day plan is not publicly confirmed by the venue. The venue’s public parking page lists event parking in Parking Structures 3 and 6/6B, gives an 8-foot garage clearance, and says overnight parking is not allowed in university parking structures/lots; this is patron/event-parking information and does not verify truck access, truck clearance, or touring parking approval. Ask the production manager/house advance and Facilities Operations Manager for truck routing, dock/freight route, parking approval, and load-in/load-out schedule.
StageUsable stage width, depth and height: UNVERIFIED. Proscenium or thrust configuration: UNVERIFIED. Deck surface: UNVERIFIED. Whether risers are required, available, or included: UNVERIFIED. Ask the venue production manager/technical director for a current stage plot, dimensions, deck details, and riser inventory/availability. No public stage specification was located on the or.
Curfews and restrictionsThe venue’s official guide states that all events have an 11:00 p.m. curfew. The organizer’s inputs of a 22:00 curtain and 150-minute show yield a nominal 00:30 end, 90 minutes after that published curfew; this is a documented schedule conflict. Obtain written confirmation of any applicable exception or revised schedule from the venue production manager/house advance.. The City of San Diego Municipal Code §59.5.0401 sets one-hour average sound-level limits measured on or beyond the producing property boundary; from 10 p.m. limits vary by receiving land use (40 dB single-family residential, 45 dB multifamily residential up to the specified density, 50 dB other residential, and 60 dB commercial). The section says those limits do not apply where the activity is otherwise authorized by a City special-event permit, development permit, or other approved permit/agreement. The receiving-zone classification and any event-specific permit conditions or exception are UNVERIFIED; the municipal code does not establish a venue-specific hard end time. Confirm applicable permit conditions with the venue production manager/house advance and the City Noise Abatement and Control Administrator.. Labor/union jurisdiction, required staffing, and staffing rules: UNVERIFIED; ask the venue production manager/house advance. No venue-specific labor rules were found in the cited public venue materials.
House-provided equipmentIncluded house PA/system (make, model, configuration and coverage): UNVERIFIED. Audio consoles: UNVERIFIED. Lighting desk and fixtures: UNVERIFIED. Backline: UNVERIFIED. Drapes: UNVERIFIED. House equipment explicitly not provided: UNVERIFIED. Public venue pages reviewed do not distinguish included equipment from rental inventory or availability. Ask the production manager/house advance for the current house inventory, what is included, what is rental/availability-only, and what is not provided.
Production contactThe venue’s official contact page names Tom Granucci as Production Manager. A direct email and direct phone for him are UNVERIFIED/not publicly listed there. Public venue contact: calcoastcuOAT@sdsu.edu; administrative office: (619) 594-0234. For this RFP’s technical advance, request the Production Manager/house advance through that venue email or office telephone. The page also lists Adrian Muñoz as Facilities Operations Manager for building/access matters.

Sources consulted:

United States

BleauLive Theater, Fontainebleau Las Vegas

Las Vegas, Nevada, USA

16 unverified

Capacity: 3,500 is the organizer-supplied planning capacity only; it is not independently verified. Fontainebleau’s 2024 lists setup-dependent capacities, including flexible orchestra theater seating of 950 and fixed seating areas of Loge 608, Lower Balcony 613, Upper Balcony 614, and Mezzanine 41. Those figures describe the listed layouts and do not validate 3,500 or a combined permitted occupancy; verify the intended configuration and approved occupancy with the venue Event Manager/box office.

RiggingRigging system/grid type, point count, maximum load per point, and theater-specific total allowable flown load: UNVERIFIED; the lists flown house audio arrays but gives no rigging plot or load limits. The touring audio/lighting/video package load is not supplied, so house capacity versus touring package, and whether ground support is required: UNVERIFIED; obtain plot/load sign-off from the venue rigger/Rigging Manager and Technical Director, comparing the actual package loads with approved limits. The pack says floor-load limits are available on request and weight calculations/verifications are the vendor’s responsibility. Heritage/designation and any heritage-related or other weight restrictions: UNVERIFIED; no such restriction is stated in the pack. Ask the venue rigger and building operations for current structural/heritage constraints and written plot approval.
PowerService amps, phase, voltage, tie-in/distro specifications and tie-in locations: UNVERIFIED; not specified in the. Generator needed: UNVERIFIED pending the touring power schedule and confirmed house service. The resort’s states Encore is the exclusive provider of event power at Fontainebleau, including temporary generator installations and hookups; confirm applicability and arrangements for this BleauLive touring engagement with Encore/house advance. Ask the head electrician/Encore production manager for a current power plot, service ratings, distro and tie-in locations, and generator determination/provider.
Load-inThe identifies dedicated theater dock spaces and a theater freight elevator; its dock diagram labels Docks 20–22. Exact theater dock-door count and clear door dimensions: UNVERIFIED. Fontainebleau’s says the resort has six shared Catering/Event docks, accepts trailers up to 53 ft, requires advance dock appointments, has no on-property truck marshaling/staging or overnight truck parking, and requires trucks to be called only when bays are available. The directs vehicles via Paradise Road and Elvis Presley Boulevard and prohibits a left turn into the dock from westbound Elvis Presley Boulevard. The theater tech pack lists one TF1 freight elevator: 15,000 lb capacity; cab 20 ft 5 in deep × 10 ft wide × 10 ft high; door 10 ft 4 in wide × 10 ft high. It also lists a TS1 service elevator: 5,000 lb capacity; cab 8 ft 5 in deep × 5 ft 9 in wide × 10 ft high; door 4 ft 6 in wide × 7 ft high. The tech pack states 8 ft height clearance from dock to stage; confirm the exact route/clearance interpretation and theater dock assignment with building operations. General dock bookings are in increments up to 4 hours, with a maximum single booking of 8 hours absent Event Manager approval; these are booking limits, not a guaranteed load-in/out window. Same-day load-in and load-out feasibility/window: UNVERIFIED. Ask the house advance/Event Manager to confirm dock/door dimensions, freight route, assigned dock slots, and a workable same-day schedule.
StageThe specifies a proscenium 72 ft wide × 43 ft 6 in high from stage, and a stage 72 ft wide × 44 ft deep × 4 ft 6 in high. A removable center apron is 12 ft deep; additional staging is available through Encore. Deck surface/material: UNVERIFIED. Thrust configuration: the pack describes a proscenium and removable apron, not a thrust; any custom thrust arrangement is UNVERIFIED. Risers required/available for this production: UNVERIFIED; ask the Technical Director/house advance for deck finish, stage plot, riser inventory and availability, and floor-load limits.
Curfews and restrictionsThe organizer’s plan supplies doors 17:30, curtain 22:00, and 150 minutes total for two acts; nominal show end is 00:30, calculated from those inputs. No venue-published hard end/curfew time or show-specific permit conditions were located, so a curfew conflict cannot be confirmed; ask the promoter/house advance and building operations for the written event-specific finish and sound conditions. Clark County’s official set octave-band maximum sound levels by zoning district and daytime/nighttime period, measured at property lines; this is not a single in-room concert dB ceiling. The code also excludes properties within its defined Gaming Enterprise District, and the parcel’s applicable zoning/district and any event-specific conditions are UNVERIFIED. Clark County’s allows conditions addressing amplified sound; it exempts qualifying resort-hotel events staged under the licensee’s supervision/control from preliminary approval, but applicable agency requirements may remain. Whether this event has permit/approval conditions is UNVERIFIED. Venue labor/union jurisdiction and any union call, staffing minimums or work rules: UNVERIFIED. The venue tech pack names Encore production personnel required for events, and the resort vendor policy requires an Encore Facility Supervisor for all load-ins/load-outs; neither document states union jurisdiction. Confirm staffing, labor jurisdiction and finish-time rules with the BleauLive Production Manager/Encore house advance.
House-provided equipmentThe lists a Meyer Sound system: 36 Panther line-array loudspeakers; 14 2100-LFC subwoofers; 10 1100-LFC subwoofers (the pack’s parenthetical says two ground-stacked arrays of three each, inconsistent with the stated count of 10—confirm deployed quantity/configuration); 2 UPQ-D1 front fills; and Ultra-X20 fills (11 stage, 10 under-balcony, 10 VIP-box). It lists DiGiCo SD12-96 house and monitor consoles, 10 Meyer MJF-210 monitors, Shure wireless/in-ear equipment, 6 wireless-mic kits, 8 wireless and 8 wired comms; Elation and Chauvet fixtures, four Robe Forte followspots, and a grandMA3 full-size desk. Video inventory includes LED walls, Barco E2/EC-30 processing, three robo cameras, and a Blackmagic 8K Constellation switcher. The pack explicitly says the theater package includes the two outboard LED walls and either the Upstage or Midstage LED wall; using both the Upstage and Midstage is additional. It does not establish event-date availability or that every other listed item is included in the package, so confirm inventory, package inclusions, operators and reservations with the Encore Manager. Soft goods listed are one full-upstage black, three sets of black legs, and a flown/bipart traveling main curtain; package inclusion/availability is UNVERIFIED. Backline: UNVERIFIED; no backline inventory is listed. Additional equipment/packages are available by inquiry. The resort states it does not lend/provide equipment or labor for truck loading/unloading; this does not establish that theater AV/backline is unavailable. Ask the Encore Manager for a written included-versus-rental list and explicit exclusions.
Production contactNamed BleauLive production contact, direct production email and phone: UNVERIFIED; no named direct contact or theater-advance phone/email is published in the reviewed or. Correct departments/roles to request: BleauLive Theater Production Manager/Technical Director, Encore production or Rigging Manager, and Fontainebleau Event Manager/house advance. The tech pack directs clients to the Encore Manager for equipment enhancements, while the BleauBook says the assigned Event Manager provides planning milestones; neither discloses a named theater contact or direct contact details.

Sources consulted:

United States

Fox Theater Oakland (1807 Telegraph Avenue)

Oakland, San Francisco Bay Area, California, USA

29 unverified

Capacity: Organizer-provided planning capacity: 2,800; not independently verified for this event configuration. The venue’s own public page advertises capacity “up to 2,800,” which is general marketing/capacity information, not confirmation of this show’s sellable or production configuration.

RiggingRigging system type: UNVERIFIED; point count: UNVERIFIED; maximum load per point: UNVERIFIED. The venue’s official technical-spec page is password-protected and does not expose the rigging documentation publicly. Whether the house can carry the touring lighting and video package: UNVERIFIED; whether ground support is required: UNVERIFIED. The touring package load is not supplied, and no public allowable house loads are available for comparison; obtain venue-rigger/technical-director plot and load sign-off before deciding. Heritage/weight restrictions: Oakland lists the Fox at 1807–1829 Telegraph Avenue as a designated landmark (Ordinance 9592, March 28, 1978); the city’s historic-property material describes design review for certain work on landmarks, but does not publish a Fox-specific rigging or weight limit. Do not treat landmark status as proof of a particular load restriction; ask the venue rigger/technical director and building operations, and confirm with Oakland Historic Preservation whether the planned attachment/installation needs review (;).
PowerService amps: UNVERIFIED; phase and voltage: UNVERIFIED; distro inventory/rating: UNVERIFIED; tie-in location and access: UNVERIFIED; generator need: UNVERIFIED; generator supplier/responsibility: UNVERIFIED. The publicly accessible official tech-spec page is password-protected and provides no power schedule. Ask the technical director/head electrician or house advance for the current power plot, tie-in details, available capacity, and generator decision/supply responsibility against the touring power requirements.
Load-inDock-door count and dimensions: UNVERIFIED; truck access/route, permitted truck size, staging/parking and overnight parking: UNVERIFIED; freight-lift dimensions/capacity or alternate route: UNVERIFIED; load-in restrictions and confirmed load-in window: UNVERIFIED. The venue’s public parking page gives patron parking, driving directions and event parking, but no production dock/truck/freight specifications; its technical-spec page is password-protected. Organizer inputs only: 34 travelling, one venue/night, same-day load-in and load-out; none is venue-confirmed. Ask the production manager/house advance for dock drawings, truck approach and parking instructions, freight/route details, any access/noise constraints, and a written same-day schedule approval.
StageUsable stage width, depth and height: UNVERIFIED; proscenium or thrust configuration: UNVERIFIED; deck surface: UNVERIFIED; risers needed/available: UNVERIFIED. No stage plot or dimensions are exposed on the password-protected official technical-spec page. Ask the venue technical director/production manager for the current stage plan, usable measurements, deck finish/load information, and riser inventory/availability.
Curfews and restrictionsJurisdiction: City of Oakland. The city’s published Entertainment Venue guidance describes permit coverage and an extended-hours application, but does not publish the Fox’s current permit, event-specific conditions, or a general exact hard end time for this concert. Oakland Municipal Code Chapter 8.18 states that persistent raucous or nerve-racking noise disturbing peace or comfort between 9:00 p.m. and 7:00 a.m. constitutes a nuisance; it also restricts noisy loading/unloading between 9:00 p.m. and 6:00 a.m. when it causes a noise disturbance across a residential property line. These are conditional nuisance provisions, not a published numeric sound limit or a venue-specific fixed curfew; the cited chapter states no dB threshold for the concert. Organizer inputs: doors 17:30, curtain 22:00, 150-minute show; the nominal show end is 00:30 on the following calendar day. No exact hard venue end/curfew was located publicly, so a direct curfew conflict is UNVERIFIED. The nominal finish is after the code’s 21:00 start of its conditional persistent-noise period, and same-day load-out timing must be checked against the conditional 21:00–06:00 loading/unloading rule. Venue-specific permit/approval conditions: UNVERIFIED; ask venue production manager/house advance for the current permit conditions and authorized end/load-out schedule, and Oakland’s Entertainment Venue permit administrator for applicable permit terms. Labor/union jurisdiction and staffing rules: UNVERIFIED; ask the house production manager/house advance for applicable agreement, required classifications, minimum calls, staffing, and overtime rules.
House-provided equipmentPA: the venue’s public marketing page says it has a Meyer sound system, but gives no model, configuration, inventory, coverage, or included/rental status; this is a general marketing claim, not a confirmed technical specification. Audio console, monitors, microphones and package details: UNVERIFIED. Lighting console, fixtures, rigging/house positions and house lighting inventory: UNVERIFIED. Video equipment: UNVERIFIED. Backline: UNVERIFIED. Drapes/soft goods: UNVERIFIED. Equipment explicitly not provided: UNVERIFIED; no public list of exclusions was found. The official tech-spec page is password-protected. Ask the production manager/technical director or house advance for the current itemized house inventory, included-versus-rental status, substitutions/availability, and explicit exclusions.
Production contactNo named production manager, technical director, head electrician, or house-advance contact is publicly disclosed in the sources reviewed; named production contact: UNVERIFIED. The venue publicly lists general inquiries at thefox@anotherplanetent.com and (510) 302-2250, but does not identify that channel as a production contact. Request routing to the Fox Theater production manager/technical director or house advance through that general venue contact. The public password-protected Tech Specs page is the official technical-document access point.

Sources consulted:

United States

Neal S. Blaisdell Arena (curtailed arena configuration)

Honolulu, Hawaii, USA

19 unverified

Capacity: 4,500 is the organizer-supplied planning capacity only; it is not independently verified. The venue’s current Arena technical sheet gives generic approximate capacities of 5,000–7,000 for a stage show and says capacities vary with staging, floor use, and safety requirements; those figures are not confirmation of this curtailed layout or the organizer’s 4,500 input.

RiggingGrid/rigging system type: UNVERIFIED. Rigging point count and maximum load per point: UNVERIFIED. Whether the house can carry the touring lighting and video package: UNVERIFIED; the package load is not supplied, and the public technical sheet gives no applicable rigging limits for comparison. Ground support required: UNVERIFIED; ask the venue rigger/technical director to review the rigging plot and package weights and provide written load sign-off, including whether ground support is required. The City master plan states the Arena has eligible historic status and says significant portions of original structures were to be preserved; it publishes no event-rigging or weight restriction, so any specific heritage/structural load restriction remains UNVERIFIED.
PowerPublished floor power: 10 wall-mounted 60-amp, 3-phase, 120/208-volt outlets distributed around the arena bowl at floor level. Published backstage services: three 400-amp, 3-phase services and two 200-amp, 3-phase services; voltage for the backstage services is UNVERIFIED. Exact distro/tie-in points, connector types, available simultaneous capacity, and service locations beyond the stated floor/backstage descriptions: UNVERIFIED. Generator need and supplier: UNVERIFIED; ask venue production/electrical staff to compare the touring power schedule with confirmed usable service and identify any generator requirement and responsible supplier.
Load-inThe Arena technical page says a truck access door at the rear allows vehicles to drive into the facility for drop-offs and pick-ups. Door count beyond that singular stated access, clear opening dimensions, dock configuration, truck route/turning clearances, and truck parking arrangements: UNVERIFIED. The venue’s general parking page says overnight parking is not allowed at the facility; whether that applies to production trucks/approved event parking must be confirmed with venue production and parking operations (;). Freight lift dimensions/capacity and any alternate freight route: UNVERIFIED. Access restrictions beyond the rear truck-door description: UNVERIFIED. Venue-specific load-in window and same-day load-in/load-out approval: UNVERIFIED; the venue says schedules are arranged in advance with Sales and Production staff. The City’s show requirements request event physical/technical information 30 days before the event and plans at least two weeks in advance (or two weeks before event where contract is signed later); ask venue Production/house advance to confirm deadlines and the actual schedule (;).
StagePublished stage dimensions are up to 60 feet wide by 40 feet deep and 4–6.5 feet high. Arena floor is a 190-foot-diameter circle; ceiling heights are stated as 47 feet above center and 60 feet above the loge rail (not stated as stage clearance). Venue describes stage-at-one-end and in-the-round configurations; proscenium dimensions/availability and suitability of the requested curtailed arrangement: UNVERIFIED. Stage deck surface: UNVERIFIED. The spec lists 4-by-8-foot platforms at various heights and mix platforms as available, but does not say whether these are risers, included, or suitable for the show; riser need/availability: UNVERIFIED. Confirm layout, deck finish, and any platform/riser inventory with Production (;).
Curfews and restrictionsThe City and County owns and operates Blaisdell Center. Honolulu Revised Ordinances §41-6.1 says sound-reproducing devices on public property are unlawful if the generated sound is audible 30 feet from the device; it specifies no dBA threshold or time-of-day cutoff in that section. The State Health Department says its noise section does not regulate sound-reproducing devices and directs such matters to Honolulu’s ordinance. Arena-specific permit conditions, application/approval requirements for this ticketed show, and an Arena hard end/curfew: UNVERIFIED. Organizer inputs give doors 17:30, curtain 22:00, and 150 minutes; nominal show end is 00:30. No Arena hard end time is documented in the sources reviewed, so a curfew conflict cannot be confirmed. Do not apply the separate Shell-only 10:00 p.m. rule to the Arena. Sound-rule applicability and event conditions should be confirmed with Blaisdell Production/house advance and the relevant City permit authority. Labour/union jurisdiction, minimum crew, calls, and staffing rules: UNVERIFIED; confirm with venue Production/house advance.
House-provided equipmentPublic Arena technical information lists LED house fixtures on dimmer control, 10 dedicated followspot positions equipped with 2K xenon Super Trouper followspots, an installed Clear-Com intercom headset system, and a paging system. It does not establish that these items are included in the rental or available for this event; confirm inclusions and availability with the venue. PA/FOH system, monitors, audio consoles, lighting console/control package beyond the stated house lighting, video/projection/LED inventory, backline, and drapes: UNVERIFIED; the technical sheet does not list them, which is not proof they are absent. The venue separately publishes equipment/personnel rental information, which should not be treated as included house equipment.
Production contactA direct named production contact, role-to-name mapping, individual email, and direct phone are UNVERIFIED. The official location page publishes a Blaisdell main line, (808) 768-5488, and displays event-management roles including Productions and Rental/Sales alongside staff names, but does not unambiguously associate a specific named person with production in the extracted listing ([127]). Ask for Blaisdell Center Productions/Production Management or the Arena technical director/house advance through the main line. For rental/sales routing, the venue publishes dessalesteam@honolulu.gov; this is not identified as a direct production email.

Sources consulted:

Cross-venue summary

Ground support

No venue is publicly confirmed as requiring ground support. Ground-support need is UNVERIFIED for all 18 venues because the actual tour lighting/video weights and point loads were not supplied and public house capacities do not constitute a package-specific engineering sign-off. Obtain each venue’s current rigging plot and a written plot/load approval from its venue rigger or technical director. Where a house cannot approve the supplied plot, confirm whether ground support is permitted and who engineers/installs it; do not assume it is allowed, especially at heritage properties.

Generator

No venue is publicly confirmed as requiring a generator. Generator need and supplier are UNVERIFIED at all 18 venues pending the touring power schedule and confirmation of usable house service/tie-in capacity. Fontainebleau states Encore is the exclusive event-power provider, including temporary generator installations and hookups; this identifies the provider to advance with, not a confirmation that a generator is needed. See the BleauLive power row and source pack.

Heritage and structural flags

Public heritage/designation sources identify the Palais Theatre (Victorian heritage registration), The Tivoli (Brisbane local heritage place), Governor Hindmarsh Hotel / The Gov (SA State Heritage Place), Astor Theatre (WA Register of Heritage Places), Burton Cummings Theatre (National Historic Site), Aragon Ballroom (contributing property in Chicago’s Uptown Square district), Greek Theatre (historic/contributing resource in Griffith Park), and Fox Theater Oakland (Oakland designated landmark) as heritage-significant or designated. Blaisdell Arena is described in the City master plan as having eligible historic status; confirm legal designation and project-specific review. The Hordern is described by the City as not heritage-listed but historically significant, adjacent to listed Centennial Parklands. These statuses do not by themselves establish a rigging weight limit. Venue-specific attachment, protection, engineering and permit restrictions remain for written confirmation. QET’s reviewed register material did not establish a protective notation or a rigging restriction; verify status as needed.

Hard-curfew conflicts with the supplied schedule

Confirmed conflict — Greek Theatre, Los Angeles: the City’s published user agreement requires performances to end by 22:30 unless SMG gives prior written permission, and sets an absolute 23:00 hard curfew. A 22:00 curtain and 150-minute show nominally ends at 00:30, after both times. Written permission for an extension beyond 22:30 does not override the stated 23:00 hard stop.

Confirmed conflict — Cal Coast Credit Union Open Air Theatre, San Diego: the venue guide states a 23:00 curfew for all events. The nominal 00:30 finish is 90 minutes later. Obtain written venue confirmation of any authorized exception or change the running schedule.

Potential booking-window conflict, not a published hard show curfew — Queen Elizabeth Theatre, Vancouver: VCT’s standard 2026/27 rental hours run 08:00–midnight, while the nominal show end is 00:30. Written extension/contract confirmation is needed for performance and load-out; public material reviewed did not call midnight a hard performance curfew.

Other venues have city noise limits, permit requirements or venue-specific conditions that may affect late sound or load-out. Where no venue-specific hard end was found, the tables say so; a general nighttime noise standard is not treated as a hard curfew.

Advance-critical confirmations

Before issuing final production assumptions, provide each venue with the touring rigging plot and itemized weights/point loads, electrical load schedule, truck/bus dimensions and quantities, stage plot, and the proposed time grid. Request written sign-off on rigging/ground-support, power/generator, truck access, same-day load-in/strike, house-equipment inclusions, labor calls, event sound conditions and end time. For the two confirmed curfew conflicts, obtain an approved exception or revise the show schedule before advancing.

References

  1. 1Operator 2026 Concert Hire Pack
  2. 2City of Sydney D/2019/831 assessment
  3. 3Hordern Pavilion Contact
  4. 4City of Port Phillip venue directory
  5. 5Victorian Heritage Database listing
  6. 6Palais Theatre venue-hire information
  7. 7EPA Victoria's current guidance
  8. 8EPA's overview
  9. 9Palais Theatre enquiry guidance
  10. 10contact page
  11. 11venue hire
  12. 12heritage citation
  13. 13venue contact
  14. 14Production Manager listing
  15. 15venue FAQ
  16. 16Council Valley venue rules
  17. 17Amplified Music Venues Local Law 2006, Schedule 1 and s.21
  18. 182026 event package
  19. 19City venue profile
  20. 20SA Heritage Places Database
  21. 21The Gov official site
  22. 22The Gov functions page
  23. 23EPA SA indoor music-noise guideline
  24. 24SA Government licensed-premises noise complaints
  25. 25venue contact page
  26. 26venue seating information
  27. 27Theatre Mode seating-plan PDF
  28. 28hire
  29. 29heritage entry
  30. 30FAQ
  31. 31City noise guidance
  32. 32official WA regulations, as at 31 March 2025
  33. 33official contact page
  34. 34October 2026 QET Technical Specifications
  35. 35Vancouver Heritage Register policy
  36. 36City temporary street-occupancy permits
  37. 37VCT 2026/27 Venue Guidelines
  38. 38Noise Control By-law 6555
  39. 39City noise by-law exception permit
  40. 40Queen Elizabeth Theatre venue page
  41. 41Noise Control By-law information
  42. 42Concert Hall
  43. 43History
  44. 44Rentals
  45. 45Getting Here
  46. 46Noise
  47. 47Noise Exemption Permits
  48. 48venue system announcement
  49. 49Rental Contacts
  50. 50official venue page
  51. 512026 Calgary Stampede Event Planning Guide
  52. 52Planning & Production Support
  53. 53City noise-exemption permit
  54. 54City noise at major events
  55. 55Calgary Stampede Venues Contact Us
  56. 562018 venue information package
  57. 57Parks Canada designation
  58. 58City bylaw 1/2008
  59. 59City noise-permit application
  60. 60Current venue rentals page
  61. 61official venue history
  62. 62venue technical guide
  63. 63Toronto Municipal Code, Chapter 591
  64. 64City noise guidance
  65. 65Noise Exemption Permits
  66. 66Book an Event / Event Services
  67. 67Contact Us
  68. 68Venue history
  69. 69Township Certificate of Appropriateness
  70. 70Venue contact
  71. 71Montclair Chapter 217
  72. 72NJDEP Noise Control Rule
  73. 73Montclair Fire permits and forms
  74. 74Private-event venue page
  75. 75MSG venue-rental page
  76. 76NYC DCP, Madison Square Garden | Penn Station Compatibility Report —2023
  77. 77NYC DEP Noise Code page
  78. 78NYC DEP Noise Code summary
  79. 79NYPD Parade and Sound Permits
  80. 80Live Nation one-sheet
  81. 81Live Nation special-events page
  82. 82Martin Audio/Technotrix account
  83. 83City district report
  84. 84City Landmarks Ordinance
  85. 85Aragon visit page
  86. 86Live Nation floor plans
  87. 87Chicago Municipal Code §8-32-080
  88. 88Chicago Municipal Code §8-32-070
  89. 89City DCASE permit page
  90. 90Live Design report
  91. 91official venue information
  92. 92City of Los Angeles, Greek Theatre User Agreement
  93. 93City Planning historic report
  94. 94official Stage private-events sheet
  95. 95LAMC §115.02
  96. 96Greek Theatre contact page
  97. 97Official venue history
  98. 98official venue contact page
  99. 99Official venue parking and directions
  100. 100official venue guide
  101. 101Official City municipal code, Noise Abatement and Control, Division 4
  102. 102City noise guidance
  103. 103BleauLive Theater tech pack
  104. 1042025 BleauBook
  105. 105vendor/contractor policy
  106. 106official dock map
  107. 107Title 30.68 noise standards
  108. 108special-event ordinance
  109. 109Event Lead Rigger — Fontainebleau Las Vegas
  110. 110Fox Theater venue information
  111. 111Fox Theater Tech Specs
  112. 112Oakland designated-landmark record
  113. 113Historic Property Regulations and Design Guidelines
  114. 114Fox Theater Parking and Directions
  115. 115Oakland Entertainment Venue and Central District Entertainment Venue guidance
  116. 116Oakland Municipal Code Chapter 8.18, Nuisances
  117. 117Fox Theater Contact
  118. 118Arena Technical Specifications, revised February 2026
  119. 119City Blaisdell Center Master Plan
  120. 120Arena Technical Information
  121. 121Blaisdell Parking Information
  122. 122Show Requirements
  123. 123City Blaisdell Center page
  124. 124Honolulu Revised Ordinances §41-6.1
  125. 125Hawaiʻi DOH Noise Forms and Links
  126. 126Rental Information
  127. 127Location and Contact Information
  128. 128City of Sydney assessment